Oscilloscope Probes

An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.Things to consider when choosing probes Ensure the probe's input connector matches the connector on your scope Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracyThe best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor. The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probeTypes of probesPassive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations: 1´: no attenuation 10´: factor-of-10 attenuation 100´: factor-of-100 attenuation 1000´: factor-of-1000 attenuationAttenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons: It allows for the measurement of a signal that might exceed the limits of the oscilloscope. The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range. Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.A current probe measures the electrical current flowing through a conductor. Tips Always use an appropriate probe tip and/or probe tip adapter whenever possible Keep ground leads short

...
Read more Read less

Filter

Visar 41 - 60 av 197 produkter
Resultat per sida
Beskrivning Pris Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Series Safety Category Rise Time
RS-artikelnummer 661-3295
Tillv. art.nrP6316
VarumärkeTektronix
6 684,70 kr
Each
Enheter
Logic, Passive - - - - P6316 - - - - - -
RS-artikelnummer 512-6438
Tillv. art.nrTT-SI 9101
VarumärkeTestec
7 472,09 kr
Each
Enheter
Active, Differential 1:10, 1:100 100MHz 1kV BNC TT-SI 9101 - CAT III 1000V ac SI CAT III 1000 V ac 3.5ns
RS-artikelnummer 518-0971
Tillv. art.nr99.00170
VarumärkeStaubli
620,99 kr
Pr. Set
Sats(er)
Passive 1:10 450MHz - BNC 99.00170 - CAT II, CAT III 600 V, 1000 V - CAT II 1000 V, CAT III 600 V 1ns
RS-artikelnummer 800-3004
Tillv. art.nrTPP0051
VarumärkeTektronix
298,70 kr
Each
Enheter
Passive 1:10 50MHz - BNC TPP0051 1 CAT II 300V - CAT II 300 V 7ns
RS-artikelnummer 136-8330
Tillv. art.nrHVFO103
VarumärkeTeledyne LeCroy
52 075,00 kr
Each
Enheter
High Voltage - 60MHz 35kV USB HVFO103 1 - - HVFO - 7.5ns
RS-artikelnummer 745-0702
Tillv. art.nrPPE6KV
VarumärkeTeledyne LeCroy
12 220,00 kr
Each
Enheter
High Voltage, Passive 1:1000 400MHz - BNC PPE6KV - CAT I - PEE CAT I -
RS-artikelnummer 797-3396
Tillv. art.nrTPP0250
VarumärkeTektronix
3 162,10 kr
Each
Enheter
Passive 1:10, 1:2 250MHz - - TPP0250 - - - TPP0 CAT II 300V -
RS-artikelnummer 661-3286
Tillv. art.nrTAP1500
VarumärkeTektronix
34 402,00 kr
Each
Enheter
Active 1:10 1.5GHz 10V - TAP1500 - - - TAP - 267ps
RS-artikelnummer 174-8871
Tillv. art.nrHVD3206A
VarumärkeTeledyne LeCroy
24 205,00 kr
Each
Enheter
Differential 1:50, 1:500 120MHz 2kV - - 1 CAT I, CAT III 1000 Vrms, 1500 V dc, 2000 V HVD3000A CAT I 2000 V, CAT III 1000 Vrms, CAT III 1500 V dc 2.9ns
RS-artikelnummer 668-7151
Tillv. art.nrP6245
VarumärkeTektronix
34 402,00 kr
Each
Enheter
Active 1:10 1.5GHz - BNC P6245 - - - - - 250ps
RS-artikelnummer 146-6616
VarumärkeRS PRO
282,00 kr
Each
Enheter
Passive 1:1, 1:10 20 MHz, 250 MHz 600V BNC - 1 CAT I 600V - CAT I 600 V 1.4 ns, 18 ns
RS-artikelnummer 187-5459
Tillv. art.nrTLP058
VarumärkeTektronix
18 643,00 kr
Each
Enheter
Logic - - - - - 8 - - - - -
RS-artikelnummer 726-0038
Tillv. art.nrTPP0200
VarumärkeTektronix
690,10 kr
Each
Enheter
Passive 1:10 200MHz 300V BNC TPP0200 - CAT II 300V TPP CAT II 300 V -
RS-artikelnummer 137-2359
Tillv. art.nrVPS410-II-B
VarumärkeFluke
2 267,56 kr
Each
Enheter
Passive 1:10 500MHz - - VPS410-II-B - CAT III, CAT IV 600 V, 1000 V VPS410 CAT III 1000 V, CAT IV 600 V -
RS-artikelnummer 725-6607
Tillv. art.nrP5050B
VarumärkeTektronix
5 551,70 kr
Each
Enheter
Passive 1:10 500MHz - BNC P5050B - CAT II 300V - CAT II 300 V -
Nytt
RS-artikelnummer 192-1271
Tillv. art.nrPP006D
VarumärkeTeledyne LeCroy
3 331,75 kr
Each
Enheter
Passive 10:1 500MHz 350 V, 1400 V BNC PP006D 1 CAT II 300V - CAT II 300 V -
RS-artikelnummer 752-7353
Tillv. art.nrTHDP0100
VarumärkeTektronix
36 771,00 kr
Each
Enheter
Differential, High Voltage 1:100, 1:1000 100MHz 6kV BNC THDP0100 - CAT I, CAT III 1000 V, 2300 V THD CAT I 2300 V, CAT III 1000 V 3.5ps
RS-artikelnummer 825-1215
Tillv. art.nr68.9434-23
VarumärkeStaubli
811,91 kr
Pr. Set
Sats(er)
Passive 1:100 500MHz - BNC 68.9434-23 1 CAT III 300V SET Isoprobe CAT III 300 V -
RS-artikelnummer 825-1203
Tillv. art.nr68.9559-23
VarumärkeStaubli
945,57 kr
Pr. Set
Sats(er)
Passive 1:100 500MHz - BNC 68.9559-23 1 CAT I, CAT III, CAT IV 600 V, 1000 V, 3540 V SET Isoprobe CAT I 3540 V, CAT III 1000 V, CAT IV 600 V -
RS-artikelnummer 146-6617
VarumärkeRS PRO
584,21 kr
Each
Enheter
Passive 1:1, 1:10 20 MHz, 250 MHz 600V BNC - 2 CAT I 600V - CAT I 600 V 1.4 ns, 18 ns
Related Products
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
For measurement of flux density and magnetic field ...
Description:
For measurement of flux density and magnetic field strength of DC,AC and peak magnetic fields in S.I c.g.s units, these two micropressor-controlled menu-driven instruments are the GM07 & GM08 series. Featuring graphical monochrome LCD display, probe polarity inidicator and operating ...
MDO3000 oscilloscopes are designed to meet users' needs ...
Description:
MDO3000 oscilloscopes are designed to meet users' needs and aspirations now and into the future. Each model is multi-functional with integrated basic spectrum analyzer, Wave Inspector Navigation, MSO, serial and parallel bus triggering and analysis, and digital voltmeter. Optional instrument ...
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial ...
Description:
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial triggering DPO2EMBD ( 575-614 ), computer serial triggering DPO2COMP ( 575-563 ) and automotive serial triggering DPO2AUTO ( 575-573 ); video out port DPO2CONN ( 575-579 ); soft carrying case ACD2000 ( ...