An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.Things to consider when choosing probes Ensure the probe's input connector matches the connector on your scope Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracyThe best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor. The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probeTypes of probesPassive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations: 1´: no attenuation 10´: factor-of-10 attenuation 100´: factor-of-100 attenuation 1000´: factor-of-1000 attenuationAttenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons: It allows for the measurement of a signal that might exceed the limits of the oscilloscope. The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range. Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.A current probe measures the electrical current flowing through a conductor. Tips Always use an appropriate probe tip and/or probe tip adapter whenever possible Keep ground leads short

...
Read more Read less

Filter

Visar 81 - 100 av 197 produkter
Resultat per sida
Beskrivning Pris Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Series Safety Category Rise Time
RS-artikelnummer 179-9557
VarumärkeRS PRO
1 223,43 kr
Each
Enheter
Passive 10:1 500MHz - BNC - 1 CAT II 400 Vrms RS-TP CAT II 400Vrms <1ns
RS-artikelnummer 174-8868
Tillv. art.nrHVD3106A-NOACC
VarumärkeTeledyne LeCroy
19 090,00 kr
Each
Enheter
Differential 1:50, 1:500 120MHz 1.5kV - - 1 CAT III - HVD3000A CAT III 1000 Vrms 2.9ns
RS-artikelnummer 174-9601
Tillv. art.nrTA375
VarumärkePico Technology
217,14 kr
Each
Enheter
Passive 1:1, 1:10 100MHz - Hook Clip TA375 1 - - - - 35ns
RS-artikelnummer 146-6615
VarumärkeRS PRO
388,00 kr
Each
Enheter
Passive 1:1, 1:10 15 MHz, 150 MHz 600V BNC - 2 CAT I 600V - CAT I 600 V 2.3 ns, 24 ns
RS-artikelnummer 146-5604
Tillv. art.nr460-004
VarumärkeDigilent
189,84 kr
Each
Enheter
Passive 1:10 6MHz - BNC - 2 - - - - -
RS-artikelnummer 137-2358
Tillv. art.nrVPS410-II-R
VarumärkeFluke
2 267,56 kr
Each
Enheter
Passive 1:10 500MHz - - VPS410-II-R - CAT III, CAT IV 600 V, 1000 V VPS410 CAT III 1000 V, CAT IV 600 V -
RS-artikelnummer 144-8208
Tillv. art.nrRT-ZP03
VarumärkeRohde & Schwarz
832,00 kr
Each
Enheter
Passive 1:1, 1:10 >300MHz - BNC RT-ZP03 1 - - RT-Z - 1.15 (300 MHz) ns, 35 (10 MHz) ns
RS-artikelnummer 898-6820
Tillv. art.nrTA133
VarumärkePico Technology
1 850,86 kr
Each
Enheter
Passive 1:10 500MHz - BNC - 1 CAT II - - - 700ps
RS-artikelnummer 922-5270
Tillv. art.nrPP026-1
VarumärkeTeledyne LeCroy
4 055,00 kr
Each
Enheter
Passive 1:10 500MHz - BNC PP026 1 CAT I, CAT II 400 Vrms, 500 Vrms - CAT I 500 Vrms, CAT II 400 Vrms 700ps
RS-artikelnummer 922-5258
Tillv. art.nrPP022-1
VarumärkeTeledyne LeCroy
4 055,00 kr
Each
Enheter
Passive 1:10 500MHz - BNC PP022 1 CAT I, CAT II 400 Vrms, 500 Vrms - CAT I 500 Vrms, CAT II 400 Vrms 700ps
RS-artikelnummer 728-6753
Tillv. art.nrP6616
VarumärkeTektronix
14 008,00 kr
Each
Enheter
Logic, Passive - - - - P6616 - - - - - -
RS-artikelnummer 179-9565
VarumärkeRS PRO
4 911,92 kr
Each
Enheter
Active 1:10, 1:100 25MHz 700V BNC - - CAT III - - - 14ns
RS-artikelnummer 898-6785
Tillv. art.nrTA223
VarumärkePico Technology
18 826,04 kr
Each
Enheter
Active 1:10 2.5GHz 20V BNC Adapter, SMA - 2 - 20V - - -
RS-artikelnummer 137-2360
Tillv. art.nrVPS410-II-G
VarumärkeFluke
2 267,56 kr
Each
Enheter
Passive 1:10 500MHz - - VPS410-II-G - CAT III, CAT IV 600 V, 1000 V VPS410 CAT III 1000 V, CAT IV 600 V -
Nytt
RS-artikelnummer 194-3333
Tillv. art.nrWS4KHD-MSO
VarumärkeTeledyne LeCroy
24 402,40 kr
Each
Enheter
Gripper - - - - - - - - - - -
RS-artikelnummer 898-6826
Tillv. art.nrTA150
VarumärkePico Technology
1 747,46 kr
Each
Enheter
Passive 1:10 350MHz - BNC - 1 CAT II - - - 1ns
RS-artikelnummer 734-5010
Tillv. art.nrTPP0850
VarumärkeTektronix
9 548,10 kr
Each
Enheter
High Voltage, Passive 1:50 800MHz 1kV - TPP0850 - CAT II 1000V ac 4000, 5000 CAT II 1000 V ac 525ps
RS-artikelnummer 745-0708
Tillv. art.nrPPE5KV
VarumärkeTeledyne LeCroy
9 840,00 kr
Each
Enheter
High Voltage, Passive 1:100 400MHz - BNC PPE5KV - CAT I - PEE CAT I -
RS-artikelnummer 744-4680
Tillv. art.nrPP011-1
VarumärkeTeledyne LeCroy
3 300,00 kr
Each
Enheter
Passive 1:10 500MHz 400V BNC PP011-1 - CAT I, CAT II 300 V ac, 400 V ac - CAT I 400 V ac, CAT II 300 V ac -
RS-artikelnummer 898-6832
Tillv. art.nrTA061
VarumärkePico Technology
2 942,56 kr
Each
Enheter
Passive 1:10 1.5GHz 12V SMA - 1 - 12V - - 240ps
Related Products
The i30 may be used in conjunction with ...
Description:
The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. ...
For measurement of flux density and magnetic field ...
Description:
For measurement of flux density and magnetic field strength of DC,AC and peak magnetic fields in S.I c.g.s units, these two micropressor-controlled menu-driven instruments are the GM07 & GM08 series. Featuring graphical monochrome LCD display, probe polarity inidicator and operating ...
MDO3000 oscilloscopes are designed to meet users' needs ...
Description:
MDO3000 oscilloscopes are designed to meet users' needs and aspirations now and into the future. Each model is multi-functional with integrated basic spectrum analyzer, Wave Inspector Navigation, MSO, serial and parallel bus triggering and analysis, and digital voltmeter. Optional instrument ...
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial ...
Description:
Tektronix MSO/DPO2000 accessories include: analysis modules embedded serial triggering DPO2EMBD ( 575-614 ), computer serial triggering DPO2COMP ( 575-563 ) and automotive serial triggering DPO2AUTO ( 575-573 ); video out port DPO2CONN ( 575-579 ); soft carrying case ACD2000 ( ...