TDK-Lambda 150 W 12 V dc AC/DC-adapter, 1 Utgång, C14 11.67 A

Mängdrabatt möjlig

Antal (1 enhet)*

1 283,96 kr

(exkl. moms)

1 604,95 kr

(inkl. moms)

Add to Basket
välj eller skriv kvantitet
I lager
  • 3 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter
Per enhet
1 - 41 283,96 kr
5 - 91 219,79 kr
10 - 241 155,62 kr
25 - 491 123,47 kr
50 +1 091,33 kr

*vägledande pris

RS-artikelnummer:
125-3764
Tillv. art.nr:
DT-150PW-120-D
Tillverkare / varumärke:
TDK-Lambda
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Varumärke

TDK-Lambda

Produkttyp

AC/DC-adapter

Kontakttyp

C14

Utspänning

12 V dc

Ström

150W

Kabellängd

170mm

Antal utgångar

1

Typ av ingångskontakt

IEC 320-C14

Minsta arbetsstemperatur

-20°C

Adapterström

11.67A

Maximal arbetstemperatur

60°C

Djup

44mm

Standarder/godkännanden

EN 55022-B, CSA 60950-1, EN 69501-1, EN 55024, UL, IEC 60950-1, FCC Class B

Bredd

44 mm

Längd

170mm

Maximal ingångsspänning

264V ac

Effektivitet

89%

Minsta ingångsspänning

90V ac

Lastreglering

5 %

Serie

DT150-D

Energieffektivitetsnivå

VI

COO (ursprungsland):
TW

TDK-Lambda Desktop Power Supply


The TDK-Lambda DT150-C series desktop power supply is the latest invention with an adapter and a voltage rating of 12VDC. This power supply provides 140W of continuous output power in a high-quality compact enclosure suitable for many general power applications. It has an input frequency range from 47Hz to 63Hz. While the input voltage rating ranging from 90VAC to 264VAC, its maximum input current is 2.5A. The device has a compact (85 x 170 x 44mm) lightweight enclosure that has ERP level V compliance, the average efficiency of 87% and a low off load standby power consumption of less than 0.5W. It has an IEC 320-C14 input connector and 1050mm cable with moulded Kykon 4-pin connector.

Note:

MTBF to MIL-HNBK (100% load, 25°C ambient).

Features and Benefits


Output current is 11.67A

Regulation is ± 5%

PFC typically 0.9 at full load (meets EN61000-3-2)

Operating temperature ranges between 0°C and 40°C at full load with no derating required

Overvoltage and short-circuit protection

Leakage current is greater than 300uA at 264VAC input

Hold up time16ms at 115VAC input

DOE level VI and EU tier 2 efficiency levels

Power factor correction

Applications


Instrumentation

Industrial device

Certifications


EN55022-B

FCC class B

Safety class I

CSA/UL60950-1

EN609501-1

IEC60950-1