Lapp 1.5 mm² 2 Core Power Cable, H07RN-F, Black Rubber, 100m
- RS-artikelnummer:
- 817-8984
- Tillv. art.nr:
- 1600199
- Tillverkare / varumärke:
- Lapp
Antal (1 rulle med 100 meter)*
3 546,05 kr
(exkl. moms)
4 432,56 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 10 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Rulle(ar) | Per rulle | Per meter* |
|---|---|---|
| 1 + | 3 546,05 kr | 35,461 kr |
*vägledande pris
- RS-artikelnummer:
- 817-8984
- Tillv. art.nr:
- 1600199
- Tillverkare / varumärke:
- Lapp
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Lapp | |
| Cross Sectional Area | 1.5 mm² | |
| Number of Cores | 2 | |
| Sheath Colour | Black | |
| Length | 100m | |
| Current Rating | 18 A | |
| Sheath Material | Rubber | |
| CPR Certification | Eca | |
| Outer Diameter | 8.5 → 11mm | |
| Voltage Rating | 450/750 V | |
| European Harmonised Code | H07RN-F | |
| Conductor Strand Type | Stranded | |
| Conductor Material | Copper | |
| Maximum Operating Temperature | +60°C | |
| Size of Strands | 0.25 mm | |
| Core Strands | 30/0.25 mm | |
| Minimum Operating Temperature | -25°C | |
| Standards Met | CE | |
| Insulation Material | Rubber | |
| Fire Behaviour | Flame Retardant | |
| Number of Strands | 30 | |
| Conductor Resistance | 13.3 Ω/km | |
| American Wire Gauge | 15 AWG | |
| Välj alla | ||
|---|---|---|
Brand Lapp | ||
Cross Sectional Area 1.5 mm² | ||
Number of Cores 2 | ||
Sheath Colour Black | ||
Length 100m | ||
Current Rating 18 A | ||
Sheath Material Rubber | ||
CPR Certification Eca | ||
Outer Diameter 8.5 → 11mm | ||
Voltage Rating 450/750 V | ||
European Harmonised Code H07RN-F | ||
Conductor Strand Type Stranded | ||
Conductor Material Copper | ||
Maximum Operating Temperature +60°C | ||
Size of Strands 0.25 mm | ||
Core Strands 30/0.25 mm | ||
Minimum Operating Temperature -25°C | ||
Standards Met CE | ||
Insulation Material Rubber | ||
Fire Behaviour Flame Retardant | ||
Number of Strands 30 | ||
Conductor Resistance 13.3 Ω/km | ||
American Wire Gauge 15 AWG | ||
- COO (Country of Origin):
- DE
H07RN-F Heavy Duty High Stress Rubber Cable
From Lapp, the H07RN-F cable is ideal for handheld and power supply devices. This heavy duty rubber sheathed cable is designed to withstand medium mechanical stress, and is often found used in challenging environments. Thanks to the cable's resistance to cold, water and UV, it can even be used for some outdoor applications.
Comprised of a harmonized fine wire copper strand with a rubber compound core insulation and outer sheath, this single-core black rubber cable is halogen free and flame resistant. Flexible and reliable, the Lapp H07RN-F cable is often used as a safe and reliable way to connect machinery and equipment to mains power.
Features and Benefits
according to EN 50525-2-21
High stresses
For protected and fixed installation permitted up to 1000V
Flame Retardant to IEC 60332-1-2
Oil-resistant according to EN 60811-404
Normativity not ozone resistant
Applications
This H07RN-F can be used for circuit proof and short to ground proof installations. The cable is environmentally resistant, and is tough enough to use in demanding application such as;
Water Treatment
Refrigerated Environments
Construction Work-sites
Stage and Studio Cabling
Agricultural and Industrial
What Does H07RN-F Mean?
H07RN-F cable is a type of harmonised cable which means it belongs to the Harmonised Reference System and conforms to the European Harmonisation Standard. This purpose of this standard is to improve standards and quality of cables across Europe to ensure the trade of common standard product.
H07RN-F is the code for this harmonised cable which breaks down into the following:
H = Harmonised
07 = 450 / 750 voltage rating
R = Natural or synthetic rubber insulation
N = Chloroprene or polychloroprene rubber sheath
F = Flexible copper conductors
Comprised of a harmonized fine wire copper strand with a rubber compound core insulation and outer sheath, this single-core black rubber cable is halogen free and flame resistant. Flexible and reliable, the Lapp H07RN-F cable is often used as a safe and reliable way to connect machinery and equipment to mains power.
Features and Benefits
High stresses
For protected and fixed installation permitted up to 1000V
Flame Retardant to IEC 60332-1-2
Oil-resistant according to EN 60811-404
Normativity not ozone resistant
Applications
This H07RN-F can be used for circuit proof and short to ground proof installations. The cable is environmentally resistant, and is tough enough to use in demanding application such as;
Water Treatment
Refrigerated Environments
Construction Work-sites
Stage and Studio Cabling
Agricultural and Industrial
What Does H07RN-F Mean?
H07RN-F cable is a type of harmonised cable which means it belongs to the Harmonised Reference System and conforms to the European Harmonisation Standard. This purpose of this standard is to improve standards and quality of cables across Europe to ensure the trade of common standard product.
H07RN-F is the code for this harmonised cable which breaks down into the following:
H = Harmonised
07 = 450 / 750 voltage rating
R = Natural or synthetic rubber insulation
N = Chloroprene or polychloroprene rubber sheath
F = Flexible copper conductors
Standards
IEC 60332-1-2, EN 60811-2-1, HD 22.4/VDE 0282-4 and HD 22.1/VDE 0282-1, HAR, RoHS, CE
relaterade länkar
- Lapp 1.5 mm² 2 Core Power Cable Black Rubber, 50m
- Lapp 1.5 mm² 4 Core Power Cable Black Rubber, 100m
- Lapp 1.5 mm² 3 Core Power Cable Black Rubber, 100m
- Lapp Power 1.5 mm² 5 Core Power Cable Black Rubber, 100m
- Lapp H07RN-F Power 2.5 mm² 2 Core Power Cable Black Rubber, 100m
- Lapp H07RN-F H07RNF 4 mm² 5 Core Power Cable Black Rubber, 100m
- Lapp 2.5 mm² 3 Core Power Cable Black Rubber, 100m
- Lapp 4 mm² 4 Core Power Cable Black Rubber, 100m
