Eaton xEffect MCB, 3P, 16A Curve D, 240 → 415V AC, 60V DC, 10 kA Breaking Capacity
- RS-artikelnummer:
- 847-3535
- Tillv. art.nr:
- 102270 FAZ-D16/3-NA
- Tillverkare / varumärke:
- Eaton
Antal (1 enhet)*
1 936,61 kr
(exkl. moms)
2 420,76 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- 2 enhet(er) levereras från den 06 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 1 936,61 kr |
*vägledande pris
- RS-artikelnummer:
- 847-3535
- Tillv. art.nr:
- 102270 FAZ-D16/3-NA
- Tillverkare / varumärke:
- Eaton
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Eaton | |
| Number of Poles | 3 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 240 → 415V | |
| Rated DC Voltage | 60V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 53.1mm | |
| Width | 105mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 76mm | |
| Terminal Contact Type | Screw | |
| Välj alla | ||
|---|---|---|
Brand Eaton | ||
Number of Poles 3 | ||
Current Rating 16A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 240 → 415V | ||
Rated DC Voltage 60V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 53.1mm | ||
Width 105mm | ||
Mounting Style DIN Rail Mount | ||
Depth 76mm | ||
Terminal Contact Type Screw | ||
Eaton MCB, 16A Current Rating, Type D Tripping - FAZ Series - 102270 FAZ-D16/3-NA
Need robust protection against equipment failure caused by electrical surges? Opt for this MCB from Eaton. As it has D-type tripping characteristics, it trips at 10 to 20 times its current rating of 16A, making it suitable for use in heavy-duty applications like control instrumentation and fluorescent lighting. An IP40 rating indicates the unit is protected against wires and tools larger than 1mm in size, reducing the risk of electric shocks during installation and maintenance.
Features & Benefits
• Designed for DIN rail mounting for ease of installation
• Broad operating temperature range of -25°C to +75°C for use in demanding environments
• Broad operating temperature range of -25°C to +75°C for use in demanding environments
How do I choose the right MCB?
There are several factors to consider when choosing your MCB. You should select a unit that has a breaking capacity and tripping characteristics that match the likely strength of any surges that may occur in your system. The MCB should also have an appropriate pole configuration for the number of circuits it will need to break in the event of an overload.
Note
Eaton formerly known as Moeller
relaterade länkar
- Eaton xEffect MCB 16A Curve D 60V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve D 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 60V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 25 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity