ifm electronic SU Series Ultrasonic Flow Meter for Liquid, 0 L/min Min, 100 L/min Max
- RS-artikelnummer:
- 740-6430
- Tillv. art.nr:
- SU8000
- Tillverkare / varumärke:
- ifm electronic
Antal (1 enhet)*
11 035,53 kr
(exkl. moms)
13 794,41 kr
(inkl. moms)
Lagerinformation är för närvarande otillgänglig
Enheter | Per enhet |
|---|---|
| 1 + | 11 035,53 kr |
*vägledande pris
- RS-artikelnummer:
- 740-6430
- Tillv. art.nr:
- SU8000
- Tillverkare / varumärke:
- ifm electronic
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | ifm electronic | |
| Media Monitored | Liquid | |
| Device Type | Ultrasonic | |
| Minimum Flow Rate | 0 L/min | |
| Maximum Flow Rate | 100 L/min | |
| Supply Voltage | 19 → 30 V dc | |
| Connection Type | 1 BSP | |
| Maximum Pressure | 16bar | |
| Material | Aluminium Alloy | |
| Minimum Media Temperature | -10 °C | |
| Maximum Media Temperature | +80°C | |
| Minimum Operating Temperature | -10°C | |
| Series | SU | |
| Maximum Operating Temperature | +60°C | |
| Välj alla | ||
|---|---|---|
Brand ifm electronic | ||
Media Monitored Liquid | ||
Device Type Ultrasonic | ||
Minimum Flow Rate 0 L/min | ||
Maximum Flow Rate 100 L/min | ||
Supply Voltage 19 → 30 V dc | ||
Connection Type 1 BSP | ||
Maximum Pressure 16bar | ||
Material Aluminium Alloy | ||
Minimum Media Temperature -10 °C | ||
Maximum Media Temperature +80°C | ||
Minimum Operating Temperature -10°C | ||
Series SU | ||
Maximum Operating Temperature +60°C | ||
- COO (Country of Origin):
- US
ifm electronic Flow Meter
The ifm electronic SU series electronic ultrasonic flow meter measures the liquid flow rate of 0L/min to 100L/min. The flow metre monitors liquid media such as water, glycol solutions, or industrial oils. It detects the 3 process categories, namely volumetric flow quantity, consumed quantity and medium temperature. The user can access and adjust the peak consumption, present consumption, or accumulated consumption via programmed switch and alarm level settings, all at the touch of a button.
Note:
Threaded (or push-fit) connecting adapters are not included with the volumetric flow sensor
Suitable connectors may be sourced (depending on the type required), for example, a G3/4 male to G3/4 female adaptor (RS stock no. 807-766), or similar
Inclusions:
2 packing washers.
Note:
Threaded (or push-fit) connecting adapters are not included with the volumetric flow sensor
Suitable connectors may be sourced (depending on the type required), for example, a G3/4 male to G3/4 female adaptor (RS stock no. 807-766), or similar
Inclusions:
2 packing washers.
Features and Benefits
Connection type is 1 BSP
Maximum operating pressure is 16bar
Maximum operating temperature is 60°C
Required supply voltage range is 19VDC to 30VDC
High accuracy, repeatability and measurement dynamics
Clearly visible LED display
It has volumetric flow quantity, total quantity and temperature indication
The process connection is G flat seal
The units feature 2 switching outputs that can be programmed as normally open or normally closed
For consumed quantity monitoring, the other output transmits counting pulses to the controller
The robust stainless steel housing and high protection rating provide high security even in harsh environments
Depending on the volumetric flow quantity to be detected, devices with different process connections are offered
Maximum operating pressure is 16bar
Maximum operating temperature is 60°C
Required supply voltage range is 19VDC to 30VDC
High accuracy, repeatability and measurement dynamics
Clearly visible LED display
It has volumetric flow quantity, total quantity and temperature indication
The process connection is G flat seal
The units feature 2 switching outputs that can be programmed as normally open or normally closed
For consumed quantity monitoring, the other output transmits counting pulses to the controller
The robust stainless steel housing and high protection rating provide high security even in harsh environments
Depending on the volumetric flow quantity to be detected, devices with different process connections are offered
Certifications
CE certified
UL listed
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
DIN IEC 68-2-27
DIN IEC 68-2-6
UL listed
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
DIN IEC 68-2-27
DIN IEC 68-2-6
relaterade länkar
- ifm electronic SU Series Ultrasonic Flow Meter for Liquid 50 L/min Max
- ifm electronic SU Series Ultrasonic Flow Meter for Liquid 200 L/min Max
- Sensirion LS32-1500 Series Liquid Flow Meter Flow Meter for Liquid 0.04 L/min Max
- Atrato Atrato Series Ultrasonic Flow Meter for Liquid 5 L/min Max
- Atrato Atrato Series Ultrasonic Flow Meter for Liquid 20 L/min Max
- Sensirion SLS-1500 Series Liquid Flow Meter Flow Meter for Liquid 40 ml/min Max
- ifm electronic SB1 Series Flow Meter for Liquid 200 L/min Max
- ifm electronic SB9 Series Flow Meter for Liquid 25 L/min Max