Sensata / Cynergy3 SSF67 Flottörbrytare Vertikal, 10 bar max. tryck Nitrilgummi (NBR) 1 m NO / NC 250 V ac 120 V dc

Denna bild representerar endast produktgruppen

Antal (1 enhet)*

3 286,26 kr

(exkl. moms)

4 107,82 kr

(inkl. moms)

Add to Basket
välj eller skriv kvantitet
Tillfälligt slut
  • 2 enhet(er) levereras från den 24 mars 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter
Per enhet
1 +3 286,26 kr

*vägledande pris

RS-artikelnummer:
756-4191
Tillv. art.nr:
SSF67A50A100
Tillverkare / varumärke:
Sensata / Cynergy3
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Varumärke

Sensata / Cynergy3

Produkttyp

Flottörbrytare

Fästetyp

Vertikal

Omkopplarutgång

NO / NC

Husmaterial

316L rostfritt stål

Kabellängd

1m

Minsta arbetsstemperatur

-20°C

Maximal arbetstemperatur

135°C

Maximal AC-spänning

250V ac

Maximal DC-spänning

120V dc

Maximal ström

600mA

Maximalt tryck

10bar

Packningsmaterial

Nitrilgummi (NBR)

Standarder/godkännanden

No

Certifiering för farligt område

Nej

Serie

SSF67

COO (ursprungsland):
CN

Dual Position Stainless Steel Float Switch


Designed to give the user a number of switching options to cater for a variety of system requirements. These switches are most suited for use with aggressive liquids and hygienic applications.

Two Independent Switching Points

Lower Float Make on Fall, and Upper Float Make on Rise

Minimum Fluid SG: 0.80

Switch Differential (each level) Nominal: 1mm

Suitable for High and Low Level Alarm and Control Signal

Stainless Steel 316L for Use with Aggressive Liquids, or in Hygienic Applications

Vertical Mounting, M16 x 2 Thread

Temperature Range: -20 to +135°C

Nitrile Gasket

’Safe Area’ for Use in Petrochemical, Storage, and Process Control Applications

Note

All ratings in tech. spec. table are for resistive loads only

Warning

The Cable entry point must NOT under any circumstances be submerged.
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside.
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid.

Relaterade länkar