Honeywell Kalibrerad
- RS-artikelnummer:
- 821-3897
- Tillv. art.nr:
- HAFBLF0050CAAX5
- Tillverkare / varumärke:
- Honeywell
För närvarande inte tillgänglig
Vi vet inte om den här artikeln kommer tillbaka i lager, RS har för avsikt att ta bort den från vårt utbud snart.
- RS-artikelnummer:
- 821-3897
- Tillv. art.nr:
- HAFBLF0050CAAX5
- Tillverkare / varumärke:
- Honeywell
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Varumärke | Honeywell | |
| Maximal flödeshastighet | 50cm³/min | |
| IsCalibrated | Ja | |
| Välj alla | ||
|---|---|---|
Varumärke Honeywell | ||
Maximal flödeshastighet 50cm³/min | ||
IsCalibrated Ja | ||
- COO (ursprungsland):
- CN
Honeywell Amplified Airflow Sensor, Dry Gas, 5V DC - HAF Series - HAFBLF0050CAAX5
Looking for a reliable high-response device for measuring the flow of air or other gas media? This amplified airflow sensor from Honeywell is designed with innovative Zephyr technology to provide highly accurate readings for mass flow of air and other non-corrosive gases. It's equipped with an advanced ASIC (application-specific integrated circuit) chip that produces a digital output at a response speed of 1ms. The sensor's compact nature means it takes up very little room on your PCB (printed circuit board), so you can use it in applications where space is limited. Its external housing is made from a high-quality polymer material that maintains resistance to chemicals and corrosion even under increased temperatures.
Features & Benefits
• Operating temperature range between -20°C and +70°C to cope with extreme conditions
• Low pressure drop reduces noise
• High stability improves overall performance and reduces errors from thermal effects
• Tubing connection style for easy integration
Applications
• HVAC (heating, ventilation, and air conditioning) filters
• Patient monitoring systems
How long can this digital airflow sensor last?
With regular maintenance, this airflow sensor will offer a long service life. The outer polymer material protects the component from damage from external sources, making it durable and suitable for use in harsh environments.
Honeywell Zephyr™ HAF Series – High Accuracy ±50 SCCM to ±750 SCCM
Honeywell Zephyr™ HAF Series sensors provide a digital interface for monitoring airflow over specified full-scale flow and compensated temperature ranges. The thermally isolated heater and temperature sensing elements help these sensors provide a fast response to air or gas flow.;Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are available at ±50, ±100, ±200, ±400 or ±750 sccm. Custom flow ranges are also available. The sensors are fully calibrated and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC).;The HAF Series is compensated over the temperature range of 0°C to 50°C and operates across a temperature range of -20°C to 70°C. The state-of-the-art ASIC-based compensation provides digital (I2C) outputs with a response time of 1 ms.;These sensors operate on the heat transfer principle to measure mass airflow. They consist of a microbridge Microelectronic and Microelectromechanical System (MEMS) with temperature-sensitive resistors deposited with thin films of platinum and silicon nitride. The MEMS sensing die is located in a precise and carefully designed airflow channel to provide repeatable response to flow.;Zephyr sensors provide the customer with enhanced reliability, high accuracy, repeatable measurements and the ability to customise sensor options to meet many specific application needs. The combination of rugged housings with a stable substrate makes these products robust. They are designed and manufactured according to ISO 9001 standards.
Features and Benefits
• Total error band as low as ±0.25%;• Fast response time;• Wide range of airflows;• Customisable flow ranges;• High sensitivity when flow is low;• Linear output provides more intuitive sensor signal;• High stability reduces errors due to thermal effects;• Low-pressure drop typically improves patient comfort in medical applications
Product Application Information
MEDICAL;• Anaesthesia delivery machines;• Ventricular assist devices (heart pumps);• Hospital diagnostics (spectrometry, gas chromatography);• Nebulisers;• Oxygen concentrators;• Patient monitoring systems (respiratory monitoring);• Sleep apnea machines;• Spirometers;• Ventilators;• Laparoscopy;INDUSTRIAL;• Air-to-fuel ratio;• Analytical instrumentation (spectrometry, chromatography);• Fuel cells;• Gas leak detection;• VAV system on HVAC systems;• Gas meters;• HVAC filters
Relaterade länkar
- Honeywell AWM5000 Med förstärkning Luftflödessensor Torr gas Kalibrerad
- Honeywell AWM5000 Med förstärkning Luftflödessensor 0L/min → Torr gas 20 L/min Kalibrerad
- Honeywell AWM5000 Med förstärkning Luftflödessensor 0L/min → Torr gas 10 L/min Kalibrerad
- Honeywell HAF Digital Luftflödessensor 0L/min → Luft, Gas 200 L/min Kalibrerad
- Honeywell HAF Digital Luftflödessensor 0L/min → Luft, Gas 10 L/min Kalibrerad
- Honeywell HAF Digital Luftflödessensor 1L/min → Luft, Gas 10 L/min Kalibrerad
- Honeywell HAF Digital Luftflödessensor 0L/min → Luft, Gas 20 L/min Kalibrerad
- Honeywell HAF Digital Luftflödessensor 0L/min → Luft, Gas 15 L/min Kalibrerad