Lascar EL-CC-1-001 Datalogg Temperatur, USB 1
- RS-artikelnummer:
- 910-7068
- Tillv. art.nr:
- EL-CC-1-001
- Tillverkare / varumärke:
- Lascar
För närvarande inte tillgänglig
Vi vet inte om den här artikeln kommer att finnas i lager igen, den har utgått från tillverkaren.
- RS-artikelnummer:
- 910-7068
- Tillv. art.nr:
- EL-CC-1-001
- Tillverkare / varumärke:
- Lascar
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Varumärke | Lascar | |
| Produkttyp | Datalogg | |
| Modellnummer | EL-CC-1-001 | |
| Noggrannhet | ±0.5°C, ±0.5 °C | |
| Antal kanaler | 1 | |
| Mätparametrar | Temperatur | |
| Gränssnittstyp | USB | |
| Dataloggertyp | Temperatur | |
| Strömkälla | Batteri | |
| IP-klassning | IP67 | |
| Minsta arbetsstemperatur | -30°C | |
| Maximal arbetstemperatur | 60°C | |
| Certifiering för farligt område | Nej | |
| Bredd | 48mm | |
| Längd | 67mm | |
| Standarder/godkännanden | No | |
| Skärmtyp | LCD | |
| Larm | Ja | |
| Batterilivslängd | 1year | |
| Antal avläsningar per kanal | 32600 | |
| Batterityp | Icke-utbytbart | |
| Välj alla | ||
|---|---|---|
Varumärke Lascar | ||
Produkttyp Datalogg | ||
Modellnummer EL-CC-1-001 | ||
Noggrannhet ±0.5°C, ±0.5 °C | ||
Antal kanaler 1 | ||
Mätparametrar Temperatur | ||
Gränssnittstyp USB | ||
Dataloggertyp Temperatur | ||
Strömkälla Batteri | ||
IP-klassning IP67 | ||
Minsta arbetsstemperatur -30°C | ||
Maximal arbetstemperatur 60°C | ||
Certifiering för farligt område Nej | ||
Bredd 48mm | ||
Längd 67mm | ||
Standarder/godkännanden No | ||
Skärmtyp LCD | ||
Larm Ja | ||
Batterilivslängd 1year | ||
Antal avläsningar per kanal 32600 | ||
Batterityp Icke-utbytbart | ||
- COO (ursprungsland):
- CN
Lascar Data Loggers
The Lascar EL-CC-1-001 chilled goods data logger comes pre-configured with sample high 8°C, low 2°C alarms with a resolution of 0.1°C. During a logging session, pressing the button will light up the status LEDs to give a quick indication of whether the temperature has exceeded an alarm condition at any point. Once a session is completed, tear open plastic wallet to reveal the USB connector and plug it into your PC. Use the free EasyLog CC software for Windows to download and graph the data and then prime your logger for its next use.
Note
EasyLog CC software is freely available for use with the Lascar EL-CC-1 range of cold chain data loggers. It is compatible with Windows XP, 7, 8 & 10. It is not compatible with Mac or Linux. Link to software download https://www. Lascar electronics. Com/software/easylog-cold-chain/
Supplied with
AA battery, measurement leads and wall mount clip
Features and Benefits
The measurement ranges between -30°C and 60°C (-22°F to 140°F)
Temperature measurement accuracy is ±0.5°C
3 data loggers for monitoring chilled goods, frozen goods and ripening goods
Number of readings per channel is 32600
No setup required. One button press-to-start logging
Pre-configured with appropriate sample rates and alarm thresholds for each application
Battery is reusable for more than 12 months
Export options include PDF, Microsoft Excel and JPEG
Applications
Refrigerated temperature monitoring
Cold chain in the food industry
Certifications
IP67 Rated
Relaterade länkar
- Lascar EL-CC-1 Datalogg Temperatur, USB 1
- Lascar EL-CC-1-002 Datalogg Temperatur, USB 1