Data Loggers

A data logger is a compact, battery powered device equipped with an internal microprocessor, data storage and one or more sensors. They can be deployed in a variety of environments to record measurements at set intervals. The devices automatically monitor and record environmental parameters over time, allowing conditions to be measured, documented, analysed and validated. The data logger contains a sensor to receive the information and a computer chip to store it. Then the information stored in the data logger is transferred to a computer for analysis. Depending on the particular data logger, measurements can include air temperature, relative humidity, AC/DC current and voltage, differential pressure, time-of-use (lights, motors, etc.), light intensity, water temperature, water level, dissolved oxygen, soil moisture, rainfall, wind speed and direction, leaf wetness, pulse signals, room occupancy, plug load, and many more.Why would you use a data logger? Data logging is the collection of data over a period of time, and is something often used in scientific experiments. Data logging systems typically monitor a process using sensors linked to a computer. Most data logging can be done automatically under computer control. Sensors have an important role in the data logging process. All physical properties can be measured with sensors such as light, heat, sound, pressure, acidity and humidity.The sensors send signals to an interface box, which is linked to a computer. The interface box converts analogue signals to digital signals that the computer can understand.The computer controlling the process will take readings at regular intervals. The time interval for data logging is the time between readings. The logging period is the total length of time over which readings are taken.The readings are stored in tables and can be displayed in graphs or passed to an application for analysis.Sometimes it is necessary to record data 'out in the field'. This is called remote data logging. Readings are stored and brought back to a computer where they are downloaded and analysed. The equipment in these situations needs to be very robust. For example equipment used to monitor water levels would have to be waterproof and equipment working in a satellite would have to be able to withstand vibration during launch and recovery. How do you use a Data Logger?● Download and install software on mobile device or laptop● Connect to data logger and launch parameters● Place in location and record data for desired period of time● Reconnect to data logger via mobile device or laptop● Download data file and readout with analysis software

...
Read more Read less

Filter

Visar 1 - 20 av 218 produkter
Resultat per sida
Beskrivning Pris Measurement Parameters Number of Input Channels Sensor Type Interface Type Maximum Temperature Measurement Maximum Voltage Measurement Best Temperature Measurement Accuracy Temperature Measurement Resolution Power Source Maximum Humidity Measurement Calibrated IP Rating Minimum Operating Temperature Maximum Operating Temperature
RS-artikelnummer 111-6765
Tillv. art.nrP01157160
VarumärkeChauvin Arnoux
27 690,52 kr
Each
Enheter
Current, Energy, Frequency, Harmonics, Power, Voltage 4, 5 Current Sensor Bluetooth, Ethernet, USB, Wi-Fi - 600 V ac @ 400 Hz, 1000 V ac @ 50/60 Hz, 1000 V dc - - From Unit Under Test, Mains - - IP67 -20°C +50°C
RS-artikelnummer 778-2699
Tillv. art.nrPEL 103
VarumärkeChauvin Arnoux
15 453,34 kr
Each
Enheter
Current, Energy, Frequency, Harmonics, Power, Voltage 6 Current Sensor Bluetooth, Ethernet, USB - 1000V ac/dc - - Mains - RSCAL IP54 - -
RS-artikelnummer 778-1034
Tillv. art.nrP01157153
VarumärkeChauvin Arnoux
14 486,34 kr
Each
Enheter
Current, Energy, Frequency, Harmonics, Power, Voltage 3, 4 Current Sensor Bluetooth, Ethernet, USB - 1000V ac/dc - - Mains - - IP54 0°C +50°C
RS-artikelnummer 536-3277
Tillv. art.nrEL-USB-4
VarumärkeLascar
657,99 kr
Each
Enheter
Current - - USB - - - - Battery - - - -35°C +80°C
RS-artikelnummer 536-8828
Tillv. art.nrADC-20 & TERM
VarumärkePico Technology
3 195,06 kr
Each
Enheter
Voltage 4, 8 - USB 1.1, USB 2.0 - ±2500mV - - USB - - - 0°C +45°C
RS-artikelnummer 810-4838
Tillv. art.nrUSB TC-08
VarumärkePico Technology
4 188,66 kr
Each
Enheter
Temperature 8 B, E, J, K, N, R, S, T USB +400 (T) °C, +910 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C - ±0.2 % 0.025°C Mains - RSCAL - - -
RS-artikelnummer 810-4841
Tillv. art.nrUSB TC-08
VarumärkePico Technology
4 188,66 kr
Each
Enheter
Temperature 8 B, E, J, K, N, R, S, T USB +400 (T) °C, +910 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C - ±0.2 % 0.025°C Mains - SYSCAL - - -
RS-artikelnummer 810-4832
Tillv. art.nrUSB TC-08
VarumärkePico Technology
4 403,66 kr
Each
Enheter
Temperature 8 B, E, J, K, N, R, S, T USB +400 (T) °C, +910 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C - ±0.2 % 0.025°C Mains - UKAS - - -
RS-artikelnummer 492-5105
Tillv. art.nrTC-08
VarumärkePico Technology
3 608,66 kr
Each
Enheter
Temperature 8 B, E, J, K, N, R, S, T USB +400 (T) °C, +910 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C - ±0.2 % 0.025°C Mains - - - - -
RS-artikelnummer 125-9517
Tillv. art.nrDAS240BAT
VarumärkeSefram
32 388,92 kr
Each
Enheter
Current, Resistance, Temperature, Thermocouple, Voltage 20 B, C, E, J, K, L, N, PT100, PT1000, S, T Ethernet, USB +400 (T) °C, +850 (PT100) °C, +850 (PT1000) °C, +900 (L) °C, +1000 (E) °C, +1200 (J) °C, +1300 (N) °C, +1370 (K) °C, +1760 (S) °C, +1820 (B) °C, +2320 (C) °C 200V 0.3 °C - Battery, Mains - - - 0°C +40°C
RS-artikelnummer 739-8607
Tillv. art.nrPP803
VarumärkePico Technology
5 056,26 kr
Each
Enheter
Current, Voltage 3 - Ethernet, USB - 1V ac - - Mains - - - 0°C +50°C
RS-artikelnummer 734-9731
Tillv. art.nrEL-USB-2-LCD+
VarumärkeLascar
1 061,25 kr
Each
Enheter
Dew Point, Humidity, Temperature - Dew Point, Humidity, Temperature USB +80 °C - ± 0.45 °C 0.5 °C, 1 °F Battery 100%RH - IP67 -35°C +80°C
RS-artikelnummer 786-5087
Tillv. art.nrWIFI-TC
VarumärkeCorintech
1 746,79 kr
Each
Enheter
Temperature 1 External Thermocouple USB / WiFi +1300 °C - ± 1.5 0.1°C Battery - - IP44 -20°C +60°C
RS-artikelnummer 500-711
Tillv. art.nrEL-USB-2-LCD
VarumärkeLascar
873,06 kr
Each
Enheter
Dew Point, Humidity, Temperature - Dew Point, Humidity, Temperature USB +80 °C - ± 0.55 °C 0.5 °C, 1 °F Battery 100%RH - IP67 -35°C +80°C
RS-artikelnummer 717-4038
Tillv. art.nrPT-104
VarumärkePico Technology
5 780,06 kr
Each
Enheter
Resistance, Temperature, Voltage 4 PT1000 Ethernet, USB +800 °C 2.5 V, 115 mV ±0.01 °C 0.001°C Mains - - - 0°C +70°C
RS-artikelnummer 466-6115
Tillv. art.nrEL-USB-1
VarumärkeLascar
483,24 kr
Each
Enheter
Temperature - Temperature USB +80 °C - ± 0.5 °C 0.5 °C, 1 °F Battery - - IP67 -35°C +80°C
RS-artikelnummer 734-9747
Tillv. art.nrEL-DataPad
VarumärkeLascar
2 082,84 kr
Each
Enheter
- - - USB - - - - Battery - - - 0°C +50°C
RS-artikelnummer 490-1070
Tillv. art.nrEL-USB-3
VarumärkeLascar
657,99 kr
Each
Enheter
Voltage - - USB - 30V dc - - Battery - - - -35°C +80°C
RS-artikelnummer 509-6961
Tillv. art.nrTGP-4104-PK
VarumärkeGemini
2 061,00 kr
Each
Enheter
Temperature 1 PT100 Serial, USB +600 °C - ±1.6 °C 0.02°C Battery - - IP68 -25°C +85°C
RS-artikelnummer 749-1914
Tillv. art.nrPP706
VarumärkePico Technology
1 127,06 kr
Each
Enheter
Digital I/O, Light, PH, Pulse, Resistance, Sound 14 - USB 2.0 +70 °C 5V ± 2 °C 0.1°C Mains - - - - -
Related Products
The kit provides accessories necessary for a straightforward ...
Description:
The kit provides accessories necessary for a straightforward single channel data logging system and comprises: EVt2 temperature data logger and EVTCRU USB Computer Interface. EVSW software for Windows is available as a download from: ... Pre-programmed logging sequence ready for ...
The Lascar EasyLog EL-SGD 70-ATP is a four-channel ...
Description:
The Lascar EasyLog EL-SGD 70-ATP is a four-channel temperature data logger with real-time readings, trend graphing and data analysis tools. It is based on the Lascar PanelPilotACE platform and includes a 7 inch panel mounted colour display with capacitive touch ...
Description:
Sold in packs of 10 data loggers, the ultra low cost EL-PDF-1-001 data logger comes with pre-configured alarms for use in Chilled environments – simply press the Start button to begin logging. The LEDs give a quick status update and ...
Temperature and humidity data loggers which are ideal ...
Description:
Temperature and humidity data loggers which are ideal for the monitoring of indoor environmental conditions. Single and dual channel temperature and humidity recorders16000 readingsUser programmable logging intervals from 1s to 10 daysDelayed and triggered start options3 stop options – stop ...