Senaste sökningar

    GEORGIN 1 Channel Double Zener Barrier, ATEX

    RS-artikelnummer:
    230-9453
    Tillv. art.nr:
    BZG756AC
    Tillverkare / varumärke:
    GEORGIN
    GEORGIN
    Se alla Zener & Galvanic Barriers
    Tillfälligt slut i lager restorder för leverans 2022-12-22
    Add to Basket
    Låda(or)

    Nästa dag-leverans inte möjlig

    Lagt till varukorgen

    Pris (ex. moms) 1 Box of 1

    1 428,98 kr

    (exkl. moms)

    1 786,22 kr

    (inkl. moms)

    Låda(or)Per Box
    1 +1 428,98 kr
    RS-artikelnummer:
    230-9453
    Tillv. art.nr:
    BZG756AC
    Tillverkare / varumärke:
    GEORGIN
    COO (Country of Origin):
    FR

    Datablad


    Lagstiftning och ursprungsland

    COO (Country of Origin):
    FR

    Produktdetaljer

    Zener barriers contribute to the intrinsic safety [Ex i] and are installed in safe areas. Their mission is to limit the level of energy that may appear in an electric circuit routed through a potentially explosive area, whatever the connection established upstream of the barrier.
    A barrier is made up of:
    - resistors that limit the current
    - Zener diodes that limit the voltage
    - fuses that protect the components

    When a fault voltage is applied across the input terminals of the barrier, the voltage that may appear in the explosive zone is limited by a Zener diode, which is in turn protected by a fuse.
    The current is limited to an acceptable value by the resistor.
    They can be installed in zone 2, thanks to the Ex nA certification in an IP 54 housing.

    Zener barrier for RTD100
    Polyester enclosure / DIN Rail mounting
    For floating potential wiring
    IS Parameters: consult us
    Metrological parameters: consult us
    Number of channels: 1
    Screw terminals

    ATEX / IECEx informations:
    INERIS 11ATEX0024X / IECEx INE11.0009X
    Group II (surface) - category (1) G/D
    II(1) GD [Ex ia Ga] IIC, IIB or [Ex iaD Da] IIIC
    II3(1) G Ex nA [ia Ga] IIC T4 Gc
    Installation in safe zone or zone 2
    For equipment installed in zone 0,1,2,20,21,22
    See leaflet for a safe use


    Specifikationer

    AttributeValue
    Barrier TypeZener Barrier
    Number of Channels1
    Maximum Current214,3mA
    Minimum Operating Temperature-20°C
    Maximum Operating Temperature60°C
    Maximum Voltage3,15V
    Hazardous Area CertificationATEX
    Operating Temperature Range-20°C to 60°C
    SeriesBZG