EPCOS, AdvanceD-MP Metal Oxide Varistor 105pF 25A, Clamping 1240V, Varistor 750V
- RS-artikelnummer:
- 711-8149
- Tillv. art.nr:
- B72210P2461K101
- Tillverkare / varumärke:
- EPCOS
För närvarande inte tillgänglig
Tyvärr, vi vet inte när detta kommer att finnas i lager igen.
- RS-artikelnummer:
- 711-8149
- Tillv. art.nr:
- B72210P2461K101
- Tillverkare / varumärke:
- EPCOS
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | EPCOS | |
| Varistor Voltage | 750V | |
| Maximum AC Voltage Rating | 460V | |
| Maximum DC Voltage Rating | 615V | |
| Clamping Voltage | 1240V | |
| Clamping Current | 25A | |
| Energy | 92J | |
| Material | Metal | |
| Series | AdvanceD-MP | |
| Diameter | 12.5mm | |
| Maximum Surge Current | 3500A | |
| Capacitance | 105pF | |
| Thickness | 8.4mm | |
| Dimensions | 12.5 (Dia.) x 8.4mm | |
| Lead Pitch | 7.5mm | |
| Välj alla | ||
|---|---|---|
Brand EPCOS | ||
Varistor Voltage 750V | ||
Maximum AC Voltage Rating 460V | ||
Maximum DC Voltage Rating 615V | ||
Clamping Voltage 1240V | ||
Clamping Current 25A | ||
Energy 92J | ||
Material Metal | ||
Series AdvanceD-MP | ||
Diameter 12.5mm | ||
Maximum Surge Current 3500A | ||
Capacitance 105pF | ||
Thickness 8.4mm | ||
Dimensions 12.5 (Dia.) x 8.4mm | ||
Lead Pitch 7.5mm | ||
Metal Oxide Varistors AdvanceD-MP series
Over voltage protection
Wide operating voltage range up to 680 VRMS
Ideally suited for AC applications where low level repetitive surges are expected
Wide operating voltage range up to 680 VRMS
Ideally suited for AC applications where low level repetitive surges are expected
Standards
Designed to meet the surge requirements of IEC 60950-1 Annex Q and IEC 60065 § 14.12
Approvals
UL approval to UL1449 (file number E321126), for use in Type 3 SPD's
The EPCOS metal oxide varistor are designed for over voltage protection .Wide operating voltage range up to 680 VRMS .Ideally suited for AC applications where low level repetitive surges are expected.
Wide operating voltage range 130 to 680 VRMS
All types duty cycle @ 6 kV/ 3 kA = Greater than 10 pulses, according to IEC 60950-1 Annex Q
All types duty cycle @ 6 kV/ 3 kA = Greater than 10 pulses, according to IEC 60950-1 Annex Q
IEC
61051-2
All types Inom @ 3 kA = Greater than 15 impulses according to UL 1449, 3rd Edition surge current
generator (8/20 μs), Type 2 listed
Multiple pulse handling capability
61051-2
All types Inom @ 3 kA = Greater than 15 impulses according to UL 1449, 3rd Edition surge current
generator (8/20 μs), Type 2 listed
Multiple pulse handling capability