Lapp UNITRONIC Series Data Cable, 10 Pairs, 20 Cores, 0.22 mm², Screened, 24 AWG, 50m, Screened Shield, Li2YCY Cable
- RS-artikelnummer:
- 807-9032
- Tillv. art.nr:
- 0031324
- Tillverkare / varumärke:
- Lapp
Antal (1 rulle med 50 meter)*
3 398,39 kr
(exkl. moms)
4 247,99 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 4 enhet(er) från den 15 december 2025
- Dessutom levereras 1 enhet(er) från den 15 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Rulle(ar) | Per rulle | Per meter* |
|---|---|---|
| 1 + | 3 398,39 kr | 67,968 kr |
*vägledande pris
- RS-artikelnummer:
- 807-9032
- Tillv. art.nr:
- 0031324
- Tillverkare / varumärke:
- Lapp
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Lapp | |
| Number of Pairs | 10 | |
| Cross Sectional Area | 0.22 mm² | |
| Number of Cores | 20 | |
| American Wire Gauge | 24 AWG | |
| Screened/Unscreened | Screened | |
| Length | 50m | |
| Shield Type | S/UTP | |
| Sheath Colour | Grey | |
| CPR Certification | Eca | |
| Cable Type | Li2YCY | |
| Outer Diameter | 10.4mm | |
| Outer Sheath Material | PVC | |
| Cable Shape | Twisted Pair | |
| Characteristic Impedance | 100 Ω | |
| Voltage Rating | 250 V | |
| Series | UNITRONIC | |
| Shielded/Unshielded | Shielded | |
| Standards Met | IEC60332-1 | |
| Fire Behaviour | Flame Retardant | |
| Välj alla | ||
|---|---|---|
Brand Lapp | ||
Number of Pairs 10 | ||
Cross Sectional Area 0.22 mm² | ||
Number of Cores 20 | ||
American Wire Gauge 24 AWG | ||
Screened/Unscreened Screened | ||
Length 50m | ||
Shield Type S/UTP | ||
Sheath Colour Grey | ||
CPR Certification Eca | ||
Cable Type Li2YCY | ||
Outer Diameter 10.4mm | ||
Outer Sheath Material PVC | ||
Cable Shape Twisted Pair | ||
Characteristic Impedance 100 Ω | ||
Voltage Rating 250 V | ||
Series UNITRONIC | ||
Shielded/Unshielded Shielded | ||
Standards Met IEC60332-1 | ||
Fire Behaviour Flame Retardant | ||
- COO (Country of Origin):
- DE
Unitronic Li2YCY Cable
From Lapp, this Unitronic Li2YCY (TP) cable is a low frequency low capacitance data cable that is well suited for wiring data systems that require a transmission of low, sensitive signals and high bit rates.
The cable has a twisted pair construction, and features a tinned-copper braided screen that protects against signal interference. It also had a PVC sheath, and is optimized for installations with limited flexibility, and for use in dry or damp interiors.
Features and Benefits
Qualified for RS422 and RS485 interfaces
Intended for limited flexible use and for fixed installation
Flame retardant to IEC 60332-1-2
Stranded 7-wire bare copper conductor
Operating temperature in fixed installations: -40°C to +80°C
Operating temperature with occasional flexing: -5°C to +70°C
Applications
Unitronic Li2YCY cable is suitable for signal, control and measuring applications, and is often used in;
Electronic circuits
Computer Systems
Machine design
Office equipment
Accessories
Unitronic cable should be used with accessories that match its capabilities, such as the Lapp range of Skintop MS-HF-M SC cable glands that have low resistance contact as standard.
136-8515 is an M12 Skintop EMC Cable Gland
136-8516 is an M16 Skintop EMC Cable Gland
136-8517 is an M20 Skintop EMC Cable Gland
136-8518 is an M25 Skintop EMC Cable Gland
136-8519 is an M32 Skintop EMC Cable Gland
The cable has a twisted pair construction, and features a tinned-copper braided screen that protects against signal interference. It also had a PVC sheath, and is optimized for installations with limited flexibility, and for use in dry or damp interiors.
Features and Benefits
Qualified for RS422 and RS485 interfaces
Intended for limited flexible use and for fixed installation
Flame retardant to IEC 60332-1-2
Stranded 7-wire bare copper conductor
Operating temperature in fixed installations: -40°C to +80°C
Operating temperature with occasional flexing: -5°C to +70°C
Applications
Unitronic Li2YCY cable is suitable for signal, control and measuring applications, and is often used in;
Electronic circuits
Computer Systems
Machine design
Office equipment
Accessories
Unitronic cable should be used with accessories that match its capabilities, such as the Lapp range of Skintop MS-HF-M SC cable glands that have low resistance contact as standard.
136-8515 is an M12 Skintop EMC Cable Gland
136-8516 is an M16 Skintop EMC Cable Gland
136-8517 is an M20 Skintop EMC Cable Gland
136-8518 is an M25 Skintop EMC Cable Gland
136-8519 is an M32 Skintop EMC Cable Gland
relaterade länkar
- Lapp UNITRONIC Series Data Cable 8 Cores Screened 50m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 16 Cores Screened 50m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 6 Cores Screened 50m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 4 Cores Screened 50m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 0.22 mm² 24 AWG Unitronic Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 4 Cores Screened 50m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 12 Cores Screened 100m Li2YCY Cable
- Lapp UNITRONIC Series Data Cable 4 Cores Screened 50m Li2YCY Cable