Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 6A Current Rating
- RS-artikelnummer:
- 323-9043
- Tillv. art.nr:
- GB2CD12
- Tillverkare / varumärke:
- Schneider Electric
Antal (1 enhet)*
542,98 kr
(exkl. moms)
678,72 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 32 enhet(er) från den 29 december 2025
- Dessutom levereras 20 enhet(er) från den 29 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 542,98 kr |
*vägledande pris
- RS-artikelnummer:
- 323-9043
- Tillv. art.nr:
- GB2CD12
- Tillverkare / varumärke:
- Schneider Electric
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 6A | |
| Number of Poles | 1P + N | |
| Voltage Rating | 250V ac | |
| Width | 15mm | |
| Series | GB2 | |
| Application | Control Circuit | |
| Tripping Mechanism | Thermal-Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 250 V, 277 V | |
| Mounting Style | DIN Rail Mount | |
| Breaking Capacity at Maximum Voltage Rating | 1 (dc) kA, 1.5 (ac) kA | |
| Rated DC Voltage | 48V | |
| Overall Dimensions | 74 x 15 x 82mm | |
| Circuit Breaker Type | Thermal Magnetic Circuit Breaker | |
| Overall Length | 74mm | |
| Overall Depth | 82mm | |
| Overall Width | 15mm | |
| Välj alla | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 6A | ||
Number of Poles 1P + N | ||
Voltage Rating 250V ac | ||
Width 15mm | ||
Series GB2 | ||
Application Control Circuit | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 250 V, 277 V | ||
Mounting Style DIN Rail Mount | ||
Breaking Capacity at Maximum Voltage Rating 1 (dc) kA, 1.5 (ac) kA | ||
Rated DC Voltage 48V | ||
Overall Dimensions 74 x 15 x 82mm | ||
Circuit Breaker Type Thermal Magnetic Circuit Breaker | ||
Overall Length 74mm | ||
Overall Depth 82mm | ||
Overall Width 15mm | ||
Uppfyller ej RoHS
- COO (Country of Origin):
- FR
GB2 Thermal Magnetic Circuit Breakers
DIN rail mounted, mechanically reset protection devices.
Short circuit and overload protection for control circuits and associated industrial equipment, e.g. solenoid valves, electric brakes and transformers, etc
Rated operational voltage of 415V
74mm high; depth 67mm (1P) 70mm (2P)
Short circuit and overload protection for control circuits and associated industrial equipment, e.g. solenoid valves, electric brakes and transformers, etc
Rated operational voltage of 415V
74mm high; depth 67mm (1P) 70mm (2P)
Standards
IEC947-2
Schneider Electric Thermal Circuit Breaker, 83A Magnetic Tripping Current, 250V AC Voltage Rating - TeSys Series - GB2CD12
Looking for a fuss-free way to safeguard your electrical networks? This thermal circuit breaker from Schneider Electric disconnects power supplies to protect equipment and limit service standstills. Simply flick the toggle switch to the ON position to reset the unit. With a mechanical lifespan of 8,000 cycles, you can use it time and again without worrying about the need for fuse changes. The device fits neatly onto a busy panel, thanks to its small size of 74 (L) x 15 (W) x 67mm (D). As it weighs in at just 70g, stress on the mounting surface is minimal.
Features & Benefits
• Voltage rating of 250V AC for compatibility with standard circuits
• IP20-rated unit assures you it's touch-safe to help prevent electric shocks
• Broad operating temperature scope between -20°C and +60°C for use in challenging conditions
• IP20-rated unit assures you it's touch-safe to help prevent electric shocks
• Broad operating temperature scope between -20°C and +60°C for use in challenging conditions
Applications
• Automated factory processes
• Medical equipment
• Electrical installations
• Medical equipment
• Electrical installations
How does a thermal circuit breaker like this one work?
The component uses bimetallic strips and an electromagnet to sense overcurrent. Voltage spikes bend these strips and the device trips the power.
relaterade länkar
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 5A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 500mA Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 8A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 3A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 10A Current Rating
- Schneider Electric Thermal Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 1A Current Rating
- Schneider Electric TeSys Thermal Circuit Breaker - GB2 2 Pole 250V Voltage Rating, 20A Current Rating
- Schneider Electric TeSys Thermal Magnetic Circuit Breaker - GB2 1P + N Pole 250V ac Voltage Rating DIN Rail Mount, 2A