Maxim Integrated MAX31865 Series RTD to Digital Converter, Digital Output, Surface Mount, 0.5°C, 20 Pins
- RS-artikelnummer:
- 167-7177
- Tillv. art.nr:
- MAX31865AAP+
- Tillverkare / varumärke:
- Maxim Integrated
Inte tillgänglig
RS kommer inte längre att lagerföra denna produkt.
- RS-artikelnummer:
- 167-7177
- Tillv. art.nr:
- MAX31865AAP+
- Tillverkare / varumärke:
- Maxim Integrated
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Maxim Integrated | |
| Sensor Function | Temperature | |
| Output Type | Digital | |
| Accuracy | 0.5°C | |
| Mounting Type | Surface Mount | |
| Pin Count | 20 | |
| Operating Temperature Range | -40 → +125 °C | |
| Minimum Operating Temperature | -40 °C | |
| Maximum Operating Temperature | +125 °C | |
| Minimum Operating Supply Voltage | 3 V | |
| Maximum Operating Supply Voltage | 3.6 V | |
| Package Type | SSOP | |
| Length | 7.33mm | |
| Series | MAX31865 | |
| Height | 1.78mm | |
| Width | 5.38mm | |
| Dimensions | 7.33 x 5.38 x 1.78mm | |
| Resolution | 15 bit | |
| Välj alla | ||
|---|---|---|
Brand Maxim Integrated | ||
Sensor Function Temperature | ||
Output Type Digital | ||
Accuracy 0.5°C | ||
Mounting Type Surface Mount | ||
Pin Count 20 | ||
Operating Temperature Range -40 → +125 °C | ||
Minimum Operating Temperature -40 °C | ||
Maximum Operating Temperature +125 °C | ||
Minimum Operating Supply Voltage 3 V | ||
Maximum Operating Supply Voltage 3.6 V | ||
Package Type SSOP | ||
Length 7.33mm | ||
Series MAX31865 | ||
Height 1.78mm | ||
Width 5.38mm | ||
Dimensions 7.33 x 5.38 x 1.78mm | ||
Resolution 15 bit | ||
The MAX31865 is an easy-to-use resistance-to-digital converter optimized for platinum resistance temperature detectors (RTDs). An external resistor sets the sensitivity for the RTD being used and a precision delta-sigma ADC converts the ratio of the RTD resistance to the reference resistance into digital form. The MAX31865's inputs are protected against overvoltage faults as large as ±45V. Programmable detection of RTD and cable open and short conditions is included.
Applications include; Industrial equipment, medical equipment & instrumentation.
Applications include; Industrial equipment, medical equipment & instrumentation.
Features & Benefits:
• Simple Conversion of Platinum RTD Resistance to Digital Value
• High Accuracy
• Over All Operating Conditions
• Integrated Fault Detection - ±45V Input Protection, Fault Detection (Open RTD Element, RTD Shorted to Out-of-Range Voltage, or Short Across RTD Element)
• Handles 100Ω to 1kΩ (at 0°C) Platinum RTDs (PT100 to PT1000)
• SPI-Compatible interface
• 15-Bit ADC resolution
• Fully Differential VREF Inputs
• High Accuracy
• Over All Operating Conditions
• Integrated Fault Detection - ±45V Input Protection, Fault Detection (Open RTD Element, RTD Shorted to Out-of-Range Voltage, or Short Across RTD Element)
• Handles 100Ω to 1kΩ (at 0°C) Platinum RTDs (PT100 to PT1000)
• SPI-Compatible interface
• 15-Bit ADC resolution
• Fully Differential VREF Inputs
Note
Please note that any defect or non – conformance of this product must be discovered and reported to RS within 20 days of purchase.