Maxim Integrated Switching Regulator, Surface Mount, 4.8 → 5.2V dc Output Voltage, 2.5V dc Input Voltage, 1
- RS-artikelnummer:
- 190-7989P
- Tillv. art.nr:
- MAX756CSA+
- Tillverkare / varumärke:
- Maxim Integrated
Mängdrabatt möjlig
Antal 10 enheter (levereras i ett rör)*
651,85 kr
(exkl. moms)
814,81 kr
(inkl. moms)
Lagerinformation är för närvarande otillgänglig
Enheter | Per enhet |
|---|---|
| 10 - 48 | 65,185 kr |
| 50 + | 51,97 kr |
*vägledande pris
- RS-artikelnummer:
- 190-7989P
- Tillv. art.nr:
- MAX756CSA+
- Tillverkare / varumärke:
- Maxim Integrated
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Maxim Integrated | |
| Output Voltage | 4.8 → 5.2V dc | |
| Input Voltage | 2.5V dc | |
| Mounting Type | Surface Mount | |
| Number of Outputs | 1 | |
| Efficiency | 87% | |
| Minimum Temperature | 0°C | |
| Maximum Temperature | +70°C | |
| Special Features | Low-Battery Detector | |
| Length | 5mm | |
| Power Signal Conversion Type | DC-DC | |
| Switching Frequency Range | 500kHz | |
| Depth | 1.5mm | |
| Width | 4mm | |
| Välj alla | ||
|---|---|---|
Brand Maxim Integrated | ||
Output Voltage 4.8 → 5.2V dc | ||
Input Voltage 2.5V dc | ||
Mounting Type Surface Mount | ||
Number of Outputs 1 | ||
Efficiency 87% | ||
Minimum Temperature 0°C | ||
Maximum Temperature +70°C | ||
Special Features Low-Battery Detector | ||
Length 5mm | ||
Power Signal Conversion Type DC-DC | ||
Switching Frequency Range 500kHz | ||
Depth 1.5mm | ||
Width 4mm | ||
Operates Down to 0.7V Input Supply Voltage
87% Efficiency at 200mA
60μA Quiescent Current
20μA Shutdown Mode with Active Reference and LBI Detector
500kHz Maximum Switching Frequency
±1.5% Reference Tolerance Over Temperature
Low-Battery Detector (LBI/LBO)
8-Pin DIP and SO Packages
Applications
2-Cell and 3-Cell Battery-Operated Equipment
3.3V to 5V Step-Up Conversion
Glucose Meters
Medical Instrumentation
Palmtop Computers
Personal Data Communicators/Computers
Portable Data-Collection Equipment
87% Efficiency at 200mA
60μA Quiescent Current
20μA Shutdown Mode with Active Reference and LBI Detector
500kHz Maximum Switching Frequency
±1.5% Reference Tolerance Over Temperature
Low-Battery Detector (LBI/LBO)
8-Pin DIP and SO Packages
Applications
2-Cell and 3-Cell Battery-Operated Equipment
3.3V to 5V Step-Up Conversion
Glucose Meters
Medical Instrumentation
Palmtop Computers
Personal Data Communicators/Computers
Portable Data-Collection Equipment