RS-artikelnummer:
480-655
Tillv. art.nr:
MCBC2450CF
Tillverkare / varumärke:
Sensata / Crydom
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Brand

Sensata / Crydom

Maximum Load Current

50 A rms

Mounting Type

Panel Mount

Maximum Load Voltage

280 V rms

Maximum Control Voltage

32 V

Control Voltage Range

8 → 32 V dc

Minimum Load Current

150 mA

Load Voltage Range

180 → 280V ac

Dimensions

58.4 x 45.7 x 19.8mm

Height

19.8mm

Maximum Operating Temperature

+80°C

Minimum Operating Temperature

-20°C

Length

58.4mm

Operating Temperature Range

-20 → +80°C

Depth

45.7mm

COO (Country of Origin):
MX

MCBC- Burst Fire Controller


This device regulates the speed of an on/off pulse. Provides a smooth proportional control that minimizes electrical noise by utilizing zero-cross detection and switching, firing only complete AC cycles. Specialized Phase Detection Circuitry allows the MCBC to be connected to only one side of the load, minimizing installation wiring. Particularly suitable for use in heating applications where the electrical noise generated by typical phase angle controllers cannot be tolerated.

Burst Fire Controller / SSR in one package
Low Voltage, current or potentiometer control
Output status indicator (load open, no voltage)
0-100% Control Range
10 AC cycle time base period
Dielectric strength 50/60Hz, input/output/base: 4000Vrms
Separate output enable / disable control
SCR based output load switching
Internal snubber network included

Note

Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet


Proportional and Power

Note

Temperature can affect current rating; please consult the data sheet for potential derating.