SNV 4076SL Safety Relay with Timed Delay

Suitable for applications that require a safe timing sequence
Meet all requirements of the currently valid safety standards EN 62061, EN ISO 13849-1, Cat 4, SIL 3, PL e
Can be used as emergency stop and safety gate monitor
Single-channel or two-channel activation through contacts or semiconductors
Automatic and manual reset with reset button monitoring
3 immediate enables, 3 enables OFF-delayed, without re-triggering
Controlled stop and time monitored door lock
Cross monitoring

Specifikationer
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Function Elevator System, Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 7
Range SafeRELAY
Reset Method Automatic, Manual, Monitored
Terminal Type Screw
Standards Met CCC, CPT, CULus, EN 50156-1, EN 62061, EN ISO 13849-1, FS, GL, GOST R, TUV
Length 45mm
Depth 96.5mm
Width 114mm
5 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
3 589,19 kr
(exkl. moms)
4 486,49 kr
(inkl. moms)
Enheter
Per unit
1 +
3 589,19 kr
Related Products
The Bulletin 100S-C safety contactors provide mechanically linked ...
Description:
The Bulletin 100S-C safety contactors provide mechanically linked positively guided contacts, required in feedback circuits of modern safety applications. The mechanically linked N.C. auxiliary contacts will not change state when a power pole welds. In addition, the gold-plated bifurcated auxiliary ...
Safety relay for two-handed controlsDuring dangerous movements, the ...
Description:
Safety relay for two-handed controlsDuring dangerous movements, the relay requires the operator to keep both hands out of the danger zoneApplications: mechanical presses, hydraulic presses, safety control circuitsRemovable terminals with connection via spring terminalsDisplay LEDs for relay statusDIN rail ...
Safety relay for two-handed controlsDuring dangerous movements, the ...
Description:
Safety relay for two-handed controlsDuring dangerous movements, the relay requires the operator to keep both hands out of the danger zoneApplications: mechanical presses, hydraulic presses, safety control circuitsRemovable terminals with connection via spring terminalsDisplay LEDs for relay statusDIN rail ...
Professional range of Schneider Preventa safety modules. The ...
Description:
Professional range of Schneider Preventa safety modules. The modules are designed for emergency stop, switch, sensing or safety light curtain monitoring. All models are highly reliable and excellent quality. IP20 Rated TerminalsIP40 Rated Enclosures.