Pilz PNOZ mm0p-T Safety Controller, 20 Safety Inputs, 4 Safety Outputs, 24 V dc
- RS-artikelnummer:
- 191-9877
- Tillv. art.nr:
- 772010
- Tillverkare / varumärke:
- Pilz
Antal (1 enhet)*
11 716,97 kr
(exkl. moms)
14 646,21 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 2 enhet(er) från den 08 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 11 716,97 kr |
*vägledande pris
- RS-artikelnummer:
- 191-9877
- Tillv. art.nr:
- 772010
- Tillverkare / varumärke:
- Pilz
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Pilz | |
| Range | PNOZ mm0p-T | |
| Number of I/O | 24 | |
| Number of Safety Inputs | 20 | |
| Number of Safety Outputs | 4 | |
| Display Type | LED | |
| Safety Category | 4 | |
| SIL | SIL 3 | |
| Expansion Available | Yes | |
| Supply Voltage | 24 V dc | |
| Contact Current Rating | 5 mA | |
| Contact Voltage Rating | 24 V dc | |
| Terminal Type | Cage Clamp, Screw | |
| IP Rating | IP20, IP54 | |
| Dimensions | 98 x 45 x 120 mm | |
| Width | 45mm | |
| Length | 98mm | |
| Depth | 120mm | |
| Välj alla | ||
|---|---|---|
Brand Pilz | ||
Range PNOZ mm0p-T | ||
Number of I/O 24 | ||
Number of Safety Inputs 20 | ||
Number of Safety Outputs 4 | ||
Display Type LED | ||
Safety Category 4 | ||
SIL SIL 3 | ||
Expansion Available Yes | ||
Supply Voltage 24 V dc | ||
Contact Current Rating 5 mA | ||
Contact Voltage Rating 24 V dc | ||
Terminal Type Cage Clamp, Screw | ||
IP Rating IP20, IP54 | ||
Dimensions 98 x 45 x 120 mm | ||
Width 45mm | ||
Length 98mm | ||
Depth 120mm | ||
RoHS-status: Undantagen
- COO (Country of Origin):
- DE
"Safety features The safety relay meets the following safety requirements The circuit is internally redundant with built-in self-monitoring. The safety device remains effective in the case of a component failure. The correct opening and closing of the safety device relays is tested automatically in each on-off cycle. "
relaterade länkar
- Pilz PNOZ ml2p Safety Controller, 24 V dc
- Pilz PNOZ Safety Controller
- Pilz PNOZ mmc3p Safety Controller 24 Safety Outputs, 24 V dc
- Pilz PNOZ mml2p Safety Controller
- Pilz PNOZ mmcxp Safety Controller
- Pilz PNOZ mmc2p Safety Controller
- Pilz PNOZ m EF Safety Controller 24 V dc
- Pilz PNOZ m ES Safety Controller 24 V dc
