Telemecanique Sensors XY2CE Rope Pull Switch, 70m, NO/NC
- RS-artikelnummer:
- 130-0879
- Tillv. art.nr:
- XY2CE6A270
- Tillverkare / varumärke:
- Telemecanique Sensors
Antal (1 enhet)*
5 991,97 kr
(exkl. moms)
7 489,96 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 1 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 5 991,97 kr |
*vägledande pris
- RS-artikelnummer:
- 130-0879
- Tillv. art.nr:
- XY2CE6A270
- Tillverkare / varumärke:
- Telemecanique Sensors
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Telemecanique Sensors | |
| Normal State Configuration | NO/NC | |
| Cable Length | 70m | |
| IP Rating | IP66 | |
| Number of Poles | DPST | |
| Series | XY2CE | |
| Range | Preventa XY2 | |
| Length | 229mm | |
| Width | 105mm | |
| Depth | 142mm | |
| Housing Material | Stainless Steel | |
| Maximum Operating Temperature | +70°C | |
| Conduit Entry | PG13.5 | |
| Dimensions | 229 x 105 x 142mm | |
| Maximum AC Voltage | 240V | |
| Minimum Operating Temperature | -25°C | |
| Standards Met | CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508 | |
| Maximum DC Voltage | 250V | |
| Välj alla | ||
|---|---|---|
Brand Telemecanique Sensors | ||
Normal State Configuration NO/NC | ||
Cable Length 70m | ||
IP Rating IP66 | ||
Number of Poles DPST | ||
Series XY2CE | ||
Range Preventa XY2 | ||
Length 229mm | ||
Width 105mm | ||
Depth 142mm | ||
Housing Material Stainless Steel | ||
Maximum Operating Temperature +70°C | ||
Conduit Entry PG13.5 | ||
Dimensions 229 x 105 x 142mm | ||
Maximum AC Voltage 240V | ||
Minimum Operating Temperature -25°C | ||
Standards Met CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508 | ||
Maximum DC Voltage 250V | ||
Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches
These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.
Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)
Note
The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.
Standards
EN/ISO 13850:2006
relaterade länkar
- Telemecanique Sensors XY2CE Rope Pull Switch NO/NC
- Telemecanique Sensors XY2CE Rope Pull Switch 2NC
- Telemecanique Sensors XY2CE Rope Pull Switch 2NO/2NC
- Telemecanique Sensors XY2 Rope Pull Switch NO/NC, Right Side
- Telemecanique Sensors XY2 Rope Pull Switch Right Side
- Telemecanique Sensors XY2 Rope Pull Switch Left Side
- Telemecanique Sensors XY2CH Rope Pull Switch NO/NC
- Telemecanique Sensors XY2CH Rope Pull Switch NO/NC