Eaton AFDD, 16A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, AFDD+ Range

Antal (1 enhet)*

1 936,61 kr

(exkl. moms)

2 420,76 kr

(inkl. moms)

Add to Basket
välj eller skriv kvantitet
I lager
  • 2 enhet(er) är redo att levereras från en annan plats
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter
Per enhet
1 +1 936,61 kr

*vägledande pris

RS-artikelnummer:
146-2818
Tillv. art.nr:
187204 AFDD-16/2/B/003-A
Tillverkare / varumärke:
Eaton
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Brand

Eaton

Current Rating

16A

Range

AFDD+

Number of Poles

2

Trip Sensitivity

30mA

Circuit Breaker Type

AFDD

Tripping Characteristics

Type B

Rated AC Voltage

240V

Mounting Style

DIN Rail Mount

Earth Leakage Protection Type

AC

Terminal Contact Type

Screw

Overall Dimensions

54 x 70 x 80mm

Reset Actuator Type

Toggle Switch

Overall Length

54mm

Application

Commercial, Residential

Overall Width

80mm

Break Time

Instantaneous

Overall Depth

70mm

Breaking Capacity at Maximum Voltage Rating

10 kA

COO (Country of Origin):
CZ

Type A & B Switch Disconnector


Professional range of Eaton Memshield incomer switch disconnectors for Type A and B distribution boards. The switch disconnectors are designed for general commercial building applications.

Eaton Arc Fault Detection Device, 2 Pole, Type B - AFDD+ Series - AFDD-16/2/B/003-A


Use this AFDD (arc fault detection device) from Eaton to keep your electrical system safe from faults and hazards. When an issue arises, the breaker detects it and disconnects the electricity. The unit contains three different circuit breakers to find different kinds of faults. Its RCD (residual current device) detects line imbalances and protects against electric shocks, while the MCB (miniature circuit breaker) prevents short circuit overloads. The AFDD is sensitive to sudden rises in current.

• LED indicator shows what kind of trip occurred
• Green-to-red switch indicators show whether the unit is on or off
• Test button for checking the device is operating correctly

How do I install this device?


Installation is straightforward – connect the neutral and line wires to the bottom of the device and the load wires to the top.

How does the LED display different faults?


In normal operation, the LED shows a green light. When you turn the switch back on after a trip, the display flashes yellow one to six times, with each number relating to a different trip cause. It identifies two types of series arc faults, a parallel arc fault, overvoltage, overheating and larger system errors.

Note

Eaton formerly known as Moeller


Memshield

relaterade länkar