RS PRO 16 mm² 2 Core Power Cable PVC
- RS-artikelnummer:
- 185-3997
- Tillverkare / varumärke:
- RS PRO
Antal (1 rulle med 100 meter)*
16 750,05 kr
(exkl. moms)
20 937,56 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 02 mars 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Rulle(ar) | Per rulle | Per meter* |
|---|---|---|
| 1 + | 16 750,05 kr | 167,501 kr |
*vägledande pris
- RS-artikelnummer:
- 185-3997
- Tillverkare / varumärke:
- RS PRO
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | RS PRO | |
| Cross Sectional Area | 16 mm² | |
| Number of Cores | 2 | |
| Armoured | Yes | |
| CPR Certification | Eca | |
| Sheath Material | PVC | |
| Outer Diameter | 20mm | |
| Voltage Rating | 1000, 600 V | |
| Conductor Strand Type | Stranded | |
| American Wire Gauge | 5 AWG | |
| Insulation Material | XLPE | |
| Cable Shape | Multicore | |
| Standards Met | BS EN 60228 | |
| Size of Strands | 1.70 mm | |
| Conductor Material | Copper | |
| Maximum Operating Temperature | +90°C | |
| Minimum Operating Temperature | -15°C | |
| Core Strands | 7/1.70 mm | |
| Välj alla | ||
|---|---|---|
Brand RS PRO | ||
Cross Sectional Area 16 mm² | ||
Number of Cores 2 | ||
Armoured Yes | ||
CPR Certification Eca | ||
Sheath Material PVC | ||
Outer Diameter 20mm | ||
Voltage Rating 1000, 600 V | ||
Conductor Strand Type Stranded | ||
American Wire Gauge 5 AWG | ||
Insulation Material XLPE | ||
Cable Shape Multicore | ||
Standards Met BS EN 60228 | ||
Size of Strands 1.70 mm | ||
Conductor Material Copper | ||
Maximum Operating Temperature +90°C | ||
Minimum Operating Temperature -15°C | ||
Core Strands 7/1.70 mm | ||
- COO (Country of Origin):
- GB
RS PRO Armoured Cable
The RS PRO 2-core armoured cable has an outer diameter of 20mm and has galvanised steel wire armour (SWA) construction. This multicore cable is polyvinyl chloride (PVC) type 9 sheathed and has a copper conductor. The nominal cross-sectional area of the conductor is 16mm² and has a voltage rating of 1kV, 600V. These cables are designed to be installed in air, clipped to surface, on cable tray/ladder work, embedded in concrete and buried direct or in the ducting underground.
Features and Benefits
• Insulation material is thermosetting XLPE Type GP8
• Minimum bend radius of 8
• Operating temperature between -15°C and 90°C
• Minimum bend radius of 8
• Operating temperature between -15°C and 90°C
Applications
• Industrial wiring
• Mains distribution
• Mains distribution
Certifications
• BS EN 60228
• BS 7655-1.3
• BS 7655-4.2
• BS 7655-1.3