Block 6 V ac 2 Output Through Hole PCB Transformer, VDE, UL 13 VA
- RS-artikelnummer:
- 201-8609
- Tillv. art.nr:
- PT 13/2/6
- Tillverkare / varumärke:
- Block
Mängdrabatt möjlig
Antal (1 enhet)*
374,00 kr
(exkl. moms)
467,50 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 11 enhet(er) från den 19 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 - 9 | 374,00 kr |
| 10 - 24 | 357,17 kr |
| 25 - 49 | 339,92 kr |
| 50 - 99 | 323,46 kr |
| 100 + | 306,32 kr |
*vägledande pris
- RS-artikelnummer:
- 201-8609
- Tillv. art.nr:
- PT 13/2/6
- Tillverkare / varumärke:
- Block
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Block | |
| Secondary Voltage | 6 V ac | |
| Product Type | PCB Transformer | |
| Primary Voltage | 230 V ac | |
| Number of Outputs | 2 | |
| Length | 56mm | |
| Width | 47 mm | |
| Depth | 40mm | |
| Power | 13VA | |
| Weight | 420g | |
| Mount Type | Through Hole | |
| Winding Type | Dual Secondary, Single Primary | |
| Maximum Operating Temperature | 40°C | |
| Efficiency | 73% | |
| Minimum Operating Frequency | 50Hz | |
| Standards/Approvals | VDE, UL | |
| Maximum Operating Frequency | 60Hz | |
| Välj alla | ||
|---|---|---|
Brand Block | ||
Secondary Voltage 6 V ac | ||
Product Type PCB Transformer | ||
Primary Voltage 230 V ac | ||
Number of Outputs 2 | ||
Length 56mm | ||
Width 47 mm | ||
Depth 40mm | ||
Power 13VA | ||
Weight 420g | ||
Mount Type Through Hole | ||
Winding Type Dual Secondary, Single Primary | ||
Maximum Operating Temperature 40°C | ||
Efficiency 73% | ||
Minimum Operating Frequency 50Hz | ||
Standards/Approvals VDE, UL | ||
Maximum Operating Frequency 60Hz | ||
- COO (Country of Origin):
- DE

Transformers PCB Mount, Short Circuit Proof, VB & PT Series
230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above
Approvals
ENEC 10; UL recognised component
Standards
EN 61558
relaterade länkar
- Block 12V ac 2 Output Through Hole PCB Transformer, 13VA
- Block 15V ac 2 Output Through Hole PCB Transformer, 13VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 7.5VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 4.5VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 6VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 1.5VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 2.3VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 3.2VA