Red Lion PAX LED Digital Panel Multi-Function Meter for Temperature, Voltage, 45mm x 92mm

Antal (1 enhet)*

3 567,98 kr

(exkl. moms)

4 459,98 kr

(inkl. moms)

Add to Basket
välj eller skriv kvantitet
Tillfälligt slut
  • 2 enhet(er) levereras från den 16 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter
Per enhet
1 +3 567,98 kr

*vägledande pris

RS-artikelnummer:
195-9188
Tillv. art.nr:
PAXLT000
Tillverkare / varumärke:
Red Lion
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Brand

Red Lion

Properties Measured

Temperature, Voltage

Display Type

LED

Cutout Height

45mm

Cutout Width

92mm

Depth

104.1mm

Number of Digits

5

Digit Height

14.2 mm

Minimum Temperature

0°C

Maximum Temperature

+50°C

Measurement Range

0 → +2315 (Type C) °C, -10 → 65 mV, -50 → +1768 (Type R) °C, -50 → +1768 (Type S) °C, -58 → +3214 (Type R) °F, -58 → +3214 (Type S) °F, -200 → +400 (Type T) °C, -200 → +760 (Type J) °C, -200 → +871 (Type E) °C, -200 → +1300 (Type N) °C, -200 → +1372 (Type K) °C, -328 → +752 (Type T) °F, -328 → +1400 (Type J) °F, -328 → +1600 (Type E) °F, -328 → +2372 (Type N) °F, -328 → +2502 (Type K) °F, +32 → +4199 (Type C) °F, +200 → +1820 (Type B) °C, +392 → +3308 (Type B) °F

Series

PAX

Minimum Measurement

0 (Type C) °C, -10 mV, -50 (Type R) °C, -50 (Type S) °C, -58 (Type R) °F, -58 (Type S) °F, -200 (Type E) °C, -200 (Type J) °C, -200 (Type K) °C, -200 (Type N) °C, -200 (Type T) °C, -328 (Type E) °F, -328 (Type J) °F, -328 (Type K) °F, -328 (Type N) °F, -328 (Type T) °F, +32 (Type C) °F, +200 (Type B) °C, +392 (Type B) °F

COO (Country of Origin):
US
The PAXLT is a versatile meter that accepts a variety of thermocouple and RTD inputs and provides a temperature display in Celsius or Fahrenheit. The readout has a 1° or 0.1° resolution. The 5-digit display has 0.56" high digits with adjustable intensity. Backlight overlay labels for °F and °C are included. The meter features a Maximum and Minimum reading memory, with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events. Either value can be displayed if desired. The display can be toggled manually or automatically between the selected values. Other features include thermocouple cold junction compensation, display offset and a programmable user input to perform a variety of meter control functions. Two setpoint outputs are provided, each with a Form C relay.

relaterade länkar