ABB Frequency, Voltage Monitoring Relay, 1, 3 Phase, SPDT
- RS-artikelnummer:
- 876-2554
- Tillv. art.nr:
- 1SVR560730R3400 CM-UFD.M22
- Tillverkare / varumärke:
- ABB
Inte tillgänglig
RS kommer inte längre att lagerföra denna produkt.
- RS-artikelnummer:
- 876-2554
- Tillv. art.nr:
- 1SVR560730R3400 CM-UFD.M22
- Tillverkare / varumärke:
- ABB
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | ABB | |
| Monitoring Application | Frequency, Voltage | |
| Electrical Phase | 1, 3 | |
| Contact Configuration | SPDT | |
| Voltage Sensitivity | Overvoltage, Undervoltage | |
| Time Delay | ±20ms | |
| Frequency Sensing Range | 40 → 60Hz | |
| Series | CM-UFD | |
| Frequency Sensitivity | Overfrequency, Underfrequency | |
| Current Range | 6.4mA | |
| Dimensions | 108 x 67 x 90mm | |
| Maximum Operating Temperature | +60°C | |
| Width | 67mm | |
| Minimum Operating Temperature | -20°C | |
| Number of Poles | 1 | |
| Special Features | Autotest Function, Monitoring of ROCOF (Rate of Change of Frequency), Multiline Backlit LCD Display | |
| Terminal Type | Screw | |
| Operating Temperature Range | +60°C | |
| Minimum Frequency Sensed | 40Hz | |
| Maximum Frequency Sensed | 60Hz | |
| Height | 90mm | |
| Minimum Voltage Sensed | 0V ac | |
| Length | 108mm | |
| Välj alla | ||
|---|---|---|
Brand ABB | ||
Monitoring Application Frequency, Voltage | ||
Electrical Phase 1, 3 | ||
Contact Configuration SPDT | ||
Voltage Sensitivity Overvoltage, Undervoltage | ||
Time Delay ±20ms | ||
Frequency Sensing Range 40 → 60Hz | ||
Series CM-UFD | ||
Frequency Sensitivity Overfrequency, Underfrequency | ||
Current Range 6.4mA | ||
Dimensions 108 x 67 x 90mm | ||
Maximum Operating Temperature +60°C | ||
Width 67mm | ||
Minimum Operating Temperature -20°C | ||
Number of Poles 1 | ||
Special Features Autotest Function, Monitoring of ROCOF (Rate of Change of Frequency), Multiline Backlit LCD Display | ||
Terminal Type Screw | ||
Operating Temperature Range +60°C | ||
Minimum Frequency Sensed 40Hz | ||
Maximum Frequency Sensed 60Hz | ||
Height 90mm | ||
Minimum Voltage Sensed 0V ac | ||
Length 108mm | ||
CM-UFD Grid Feeding Relays
The expertly designed CM-UFD range of grid feeding relays ensures safe and reliable monitoring of numerous grid parameters when feeding energy into the public grid.
Main features include-
Monitoring of voltage and frequency in single and three-phase mains (2-wire, 3-wire, or 4-wire AC systems)
0-minutes average value monitoring
Rate of change of frequency monitoring configurable
Vector shift detection configurable
Error memory for up to 99 entries
Password protection available
Monitoring of voltage and frequency in single and three-phase mains (2-wire, 3-wire, or 4-wire AC systems)
0-minutes average value monitoring
Rate of change of frequency monitoring configurable
Vector shift detection configurable
Error memory for up to 99 entries
Password protection available
relaterade länkar
- ABB Frequency 1 SPDT, DIN Rail
- ABB Voltage Monitoring Relay SPDT
- ABB Phase 3 Phase, 2CO (SPDT)
- ABB Frequency 1 SPDT 99.9 → 415 V dc, DIN Rail
- Carlo Gavazzi Frequency 3 Phase DIN Rail
- ATC Frequency Voltage Monitoring Relay SPDT DIN Rail
- Siemens Frequency Voltage Monitoring Relay SPDT DIN Rail
- Carlo Gavazzi Frequency Voltage Monitoring Relay SPDT DIN Rail