Finder Voltage Monitoring Relay, 3 Phase, SPDT, 300 → 480V ac
- RS-artikelnummer:
- 789-2742
- Tillv. art.nr:
- 70.31.8.400.2022
- Tillverkare / varumärke:
- Finder
Antal (1 enhet)*
1 177,12 kr
(exkl. moms)
1 471,40 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 19 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 1 177,12 kr |
*vägledande pris
- RS-artikelnummer:
- 789-2742
- Tillv. art.nr:
- 70.31.8.400.2022
- Tillverkare / varumärke:
- Finder
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Finder | |
| Monitoring Application | Voltage | |
| Electrical Phase | 3 | |
| Contact Configuration | SPDT | |
| Voltage Sensing Range | 300 → 480V ac | |
| Voltage Sensitivity | Overvoltage Protection, Undervoltage Protection | |
| Phase Sensitivity | Phase Loss, Phase Sequence | |
| Time Delay | 0.5 → 60s | |
| Frequency Sensing Range | 50 → 60Hz | |
| Series | 70 | |
| Length | 88.8mm | |
| Minimum Operating Temperature | -20°C | |
| Current Range | 6A | |
| Dimensions | 60.8 x 35 x 88.8mm | |
| Width | 35mm | |
| Maximum Operating Temperature | +60°C | |
| Height | 60.8mm | |
| Operating Temperature Range | +60°C | |
| Maximum Voltage Sensed | 480V ac | |
| Välj alla | ||
|---|---|---|
Brand Finder | ||
Monitoring Application Voltage | ||
Electrical Phase 3 | ||
Contact Configuration SPDT | ||
Voltage Sensing Range 300 → 480V ac | ||
Voltage Sensitivity Overvoltage Protection, Undervoltage Protection | ||
Phase Sensitivity Phase Loss, Phase Sequence | ||
Time Delay 0.5 → 60s | ||
Frequency Sensing Range 50 → 60Hz | ||
Series 70 | ||
Length 88.8mm | ||
Minimum Operating Temperature -20°C | ||
Current Range 6A | ||
Dimensions 60.8 x 35 x 88.8mm | ||
Width 35mm | ||
Maximum Operating Temperature +60°C | ||
Height 60.8mm | ||
Operating Temperature Range +60°C | ||
Maximum Voltage Sensed 480V ac | ||
- COO (ursprungsland):
- IT
Finder Series 70 Monitoring Relay, 300 to 480V AC Voltage Sensing Range, 6A Current - 70.31.8.400.2022
This monitoring relay is an advanced voltage sensing device designed for 3-phase systems. Compactly built with dimensions of 60.8 x 35 x 88.8mm, it effectively safeguards electrical installations by monitoring voltage levels and providing crucial protection against both overvoltage and undervoltage conditions.
Features & Benefits
• Accommodates a voltage sensing range from 300 to 480V AC
• Offers overvoltage and undervoltage protection for enhanced safety
• Capable of detecting phase loss and phase sequence issues
• Features a time delay adjustment of 0.5 to 60 seconds
• Equipped with coloured LEDs for clear visual fault indication
• Compact design with modular housing for easy mounting
• Offers overvoltage and undervoltage protection for enhanced safety
• Capable of detecting phase loss and phase sequence issues
• Features a time delay adjustment of 0.5 to 60 seconds
• Equipped with coloured LEDs for clear visual fault indication
• Compact design with modular housing for easy mounting
Applications
• Ideal for wood-processing machines requiring voltage regulation
• Utilised in hoists and cranes for safe operation
• Suitable for control panels associated with pumps
• Effective for monitoring escalators and forced-air ventilators
• Employed in air conditioning systems to prevent voltage irregularities
• Utilised in hoists and cranes for safe operation
• Suitable for control panels associated with pumps
• Effective for monitoring escalators and forced-air ventilators
• Employed in air conditioning systems to prevent voltage irregularities
What is the maximum operating temperature for this relay?
The maximum operating temperature for the relay is +60 °C, ensuring reliable performance even in demanding environments.
How does the phase loss detection feature work?
The phase loss detection immediately turns off the output relay when a phase is lost, ensuring protection of connected equipment, and restores the relay as soon as the phase is active again.
What adjustments can be made to enhance its functionality?
The relay allows users to easily adjust settings for voltage detection levels and delay times using a front-facing selector and trimmers, providing tailored operation.
Is this device suitable for single-phase applications as well?
This relay is specifically designed for three-phase applications and is not intended for single-phase use, optimising its performance in complex electrical systems.
relaterade länkar
- Finder Voltage Monitoring Relay SPDT, 300 → 480V ac
- Allen Bradley Voltage Monitoring Relay SPDT, 440 → 480V ac
- Finder Voltage Monitoring Relay DPDT DIN Rail
- Finder Voltage Monitoring Relay SPDT
- Omron Phase Three Phase 220 → 480V ac, DIN Rail
- Omron Phase SPDT DIN Rail
- Finder Voltage Monitoring Relay SPDT, DIN Rail
- GIC Voltage Monitoring Relay SPDT DIN Rail