Broyce Control Voltage Monitoring Relay, 3PST, DIN Rail
- RS-artikelnummer:
- 188-3544
- Tillv. art.nr:
- LR44/3 100-230V AC/DC
- Tillverkare / varumärke:
- Broyce Control
Antal (1 enhet)*
743,50 kr
(exkl. moms)
929,38 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 3 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 743,50 kr |
*vägledande pris
- RS-artikelnummer:
- 188-3544
- Tillv. art.nr:
- LR44/3 100-230V AC/DC
- Tillverkare / varumärke:
- Broyce Control
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Broyce Control | |
| Monitoring Application | Voltage | |
| Contact Configuration | 3PST | |
| Mounting Type | DIN Rail | |
| Time Delay | 1s | |
| Frequency Sensing Range | 48 → 63Hz | |
| Series | 44 | |
| Current Range | Maximum of 5A | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | -20°C | |
| Height | 85mm | |
| Width | 44mm | |
| Operating Temperature Range | +60°C | |
| Minimum Frequency Sensed | 48Hz | |
| Dimensions | 63.5 x 44 x 85mm | |
| Maximum Operating Temperature | +60°C | |
| Maximum Frequency Sensed | 63Hz | |
| Length | 63.5mm | |
| Number of Poles | 1 | |
| Välj alla | ||
|---|---|---|
Brand Broyce Control | ||
Monitoring Application Voltage | ||
Contact Configuration 3PST | ||
Mounting Type DIN Rail | ||
Time Delay 1s | ||
Frequency Sensing Range 48 → 63Hz | ||
Series 44 | ||
Current Range Maximum of 5A | ||
Terminal Type Screw | ||
Minimum Operating Temperature -20°C | ||
Height 85mm | ||
Width 44mm | ||
Operating Temperature Range +60°C | ||
Minimum Frequency Sensed 48Hz | ||
Dimensions 63.5 x 44 x 85mm | ||
Maximum Operating Temperature +60°C | ||
Maximum Frequency Sensed 63Hz | ||
Length 63.5mm | ||
Number of Poles 1 | ||
- COO (Country of Origin):
- GB
The product is designed to monitor the status of the externally wired contacts and operate/alternate the output relays in turn on each closure of the contact. A help function is included such that it allows the second and third relay to energize when the other contacts are closed. An auxiliary supply (required to power the unit) must be present for the product to function.
Logic Relay designed to balance wear between motors, compressors and generators
Monitors 3 external N.O. contacts
Isolated Auxiliary supply
3 x SPNO Relay outputs
44mm wide, DIN Rail mount
Monitors 3 external N.O. contacts
Isolated Auxiliary supply
3 x SPNO Relay outputs
44mm wide, DIN Rail mount
relaterade länkar
- Broyce Control Voltage Monitoring Relay DIN Rail
- Broyce Control Voltage Monitoring Relay DIN Rail
- Broyce Control Phase 1 Phase DIN Rail
- Broyce Control Phase 3 Phase DIN Rail
- Broyce Control Temperature Monitoring Relay DIN Rail
- Broyce Control Voltage Monitoring Relay SPDT DIN Rail
- Broyce Control Voltage Monitoring Relay Maximum of 230V ac
- Broyce Control Voltage Monitoring Relay 12 → 24V dc, DIN Rail