Eaton xEffect FAZ Miniature Circuit Breaker, 2-Pole, 500 mA, Type C, 415 V ac AC, 96 V DC, 10 kA Breaking Capacity
- RS-artikelnummer:
- 922-7119
- Tillv. art.nr:
- 278743 FAZ-C0,5/2
- Tillverkare / varumärke:
- Eaton
Antal (1 enhet)*
1 212,65 kr
(exkl. moms)
1 515,81 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 2 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 1 212,65 kr |
*vägledande pris
- RS-artikelnummer:
- 922-7119
- Tillv. art.nr:
- 278743 FAZ-C0,5/2
- Tillverkare / varumärke:
- Eaton
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Eaton | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 2 | |
| Current Rating | 500 mA | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 415 V ac | |
| Rated DC Voltage | 96 V | |
| Breaking Capacity | 10kA | |
| Mount Type | DIN Rail | |
| Range | xEffect | |
| Series | FAZ | |
| Terminal Type | Twin-Purpose Terminal | |
| IP Rating | IP20 | |
| Depth | 80mm | |
| Width | 66 mm | |
| Standards/Approvals | No | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| Break Time | Instantaneous | |
| Välj alla | ||
|---|---|---|
Brand Eaton | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 2 | ||
Current Rating 500 mA | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 415 V ac | ||
Rated DC Voltage 96 V | ||
Breaking Capacity 10kA | ||
Mount Type DIN Rail | ||
Range xEffect | ||
Series FAZ | ||
Terminal Type Twin-Purpose Terminal | ||
IP Rating IP20 | ||
Depth 80mm | ||
Width 66 mm | ||
Standards/Approvals No | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
Break Time Instantaneous | ||
Eaton Miniature Circuit Breakers (MCBs) - FAZ Series
The FAZ series of miniature circuit breakers (MCBs) from Eatons xEffect range has a current limiting design providing fast short-circuit interruption that reduces the let-through electrical energy and overload currents that can damage the circuit.
Ideally suited to control circuits and electrical distribution boards the FAZ series of MCBs offer a wide range of diverse protection characteristics, protecting your electrical equipment against overload damage. For additional safety, the MCB breaker cannot be defeated by holding the handle in the ON position, these MCBs are also finger proof and have a trip-free mechanism.
These MCBs have both a thermal and electromagnetic release, with rated currents of 0.16 A up to 63 A and a switching capacity of 15kA or 10kA depending on the device type.
The FAZ series includes miniature circuit breakers, interlocks, busbars and snap-on accessories including auxiliaries and tripping modules.
Features and Benefits
• Thermal-magnetic overcurrent protection
• Power to the miniature circuit breakers can be fed from the line or load side
• Clear indication of contact position via front switch toggle
• Easy installation on DIN rail. MCB module width of only 17.5 mm (per pole)
• Six levels of short-circuit protection, categorized by Type B, C, D, K, S and Z curves
• Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
• Available in single pole up to 4 pole
• Dual rating for IEC 60947-2 standard
• MCB Module widths: 1P 17.5mm, 2P 35mm and 3P 52.5mm
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar installations. In the UK these are traditionally known as miniature circuit breakers (MCBs), moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Note
Eaton formerly known as Moeller
Standards
IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2
Relaterade länkar
- Eaton xEffect MCB 500mA Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 500mA Curve C 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 500mA Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 12A Curve C 96V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 32A Curve C 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 4A Curve B 96V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 500mA Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 500mA Curve D 10 kA Breaking Capacity