Eaton xEffect MCB, 2P, 16A Curve B, 240 → 415V AC, 10 kA Breaking Capacity
- RS-artikelnummer:
- 847-3147
- Tillv. art.nr:
- 278734 FAZ-B16/2
- Tillverkare / varumärke:
- Eaton
Antal (1 enhet)*
803,49 kr
(exkl. moms)
1 004,36 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 6 enhet(er) är redo att levereras från en annan plats
- Dessutom levereras 5 enhet(er) från den 10 februari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 803,49 kr |
*vägledande pris
- RS-artikelnummer:
- 847-3147
- Tillv. art.nr:
- 278734 FAZ-B16/2
- Tillverkare / varumärke:
- Eaton
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Eaton | |
| Number of Poles | 2 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 240 → 415V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 36mm | |
| Width | 85mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 73mm | |
| Model Number | 278734 | |
| Application | Commercial, Residential | |
| Välj alla | ||
|---|---|---|
Brand Eaton | ||
Number of Poles 2 | ||
Current Rating 16A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 240 → 415V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 36mm | ||
Width 85mm | ||
Mounting Style DIN Rail Mount | ||
Depth 73mm | ||
Model Number 278734 | ||
Application Commercial, Residential | ||
Eaton 2-Pole MCB, 16A Current Rating, B Curve - FAZ Series - 278734 FAZ-B16/2
Features & Benefits
• Needs only a small mounting width per pole of 17.5mm for maximum packing efficiency on a DIN rail
• Nylon housing resists corrosion, so is compatible with moist operating conditions
• Easy trouble-shooting, thanks to its colour-coded status indicator
• Captive screw terminals to help reduce the chance of screws being lost when they're unfastened
What's the difference between a B-curve and a C-curve circuit breaker?
A B-curve breaker like this one is suitable for tripping small current surges, reacting at 3 to 5 times its rated current. A C-curve device safeguards against larger surges and trips at 5 to 10 the current rating.
Eaton FAZ Series Circuit Breakers
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eatons FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
Features and Benefits
• The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
• Rated currents up to 63A.
• The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
• Reliable and safe operation with six levels of thermal-magnetic over-current protection.
• Red or green light indicates the contact position.
• Easy installation.
• Suitable for supplementary protection.
Note
Eaton formerly known as Moeller
relaterade länkar
- Eaton xEffect FAZ MCB 16A Curve B 60V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve B 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve D 10 kA Breaking Capacity
- Eaton xEffect MCB 15A Curve C 415V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve B 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 16A Curve D 60V DC, 15 kA Breaking Capacity