Allen Bradley 1492-D2 1492-D MCB, 2P, 13A Curve C, 10 kA Breaking Capacity
- RS-artikelnummer:
- 218-8555
- Tillv. art.nr:
- 1492-D2C130
- Tillverkare / varumärke:
- Allen Bradley
Antal (1 enhet)*
1 780,24 kr
(exkl. moms)
2 225,30 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 13 mars 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 1 780,24 kr |
*vägledande pris
- RS-artikelnummer:
- 218-8555
- Tillv. art.nr:
- 1492-D2C130
- Tillverkare / varumärke:
- Allen Bradley
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Allen Bradley | |
| Number of Poles | 2 | |
| Current Rating | 13A | |
| Tripping Characteristics | Type C | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | 1492-D2 | |
| Series | 1492-D | |
| Circuit Breaker Type | MCB | |
| Length | 88mm | |
| Width | 17.5mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 69mm | |
| Model Number | 1492-D2C130 | |
| Välj alla | ||
|---|---|---|
Brand Allen Bradley | ||
Number of Poles 2 | ||
Current Rating 13A | ||
Tripping Characteristics Type C | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range 1492-D2 | ||
Series 1492-D | ||
Circuit Breaker Type MCB | ||
Length 88mm | ||
Width 17.5mm | ||
Mounting Style DIN Rail Mount | ||
Depth 69mm | ||
Model Number 1492-D2C130 | ||
RoHS-status: Inte relevant
- COO (Country of Origin):
- DE
The Rockwell Automation 1492-D series miniature circuit breakers provide overcurrent and short circuit protection for higher voltage DC circuits. It has two pole and current rating of 13 may be used with UL 508 Listed bus bars for convenience in panel assembly, a wide range of left-, right- and space saving bottom-mount accessories, and lock out attachments for safety during maintenance.
Dual terminals provide a more secure connection of up to four wires, or two wires and a bus bar
Existing installations can be easily upgraded to include an auxiliary using the bottom mounted auxiliary contact options, which require no DIN Rail space
Installation of up to six accessories on the same circuit breaker
Superior shock and vibration resistance to prevent nuisance tripping
Terminal design helps prevent wiring misses by directing wires into the terminal openings, even while tightening
RoHS compliant and fully-recyclable device
Existing installations can be easily upgraded to include an auxiliary using the bottom mounted auxiliary contact options, which require no DIN Rail space
Installation of up to six accessories on the same circuit breaker
Superior shock and vibration resistance to prevent nuisance tripping
Terminal design helps prevent wiring misses by directing wires into the terminal openings, even while tightening
RoHS compliant and fully-recyclable device
relaterade länkar
- Allen Bradley 1492-SP 1492-SPM MCB 13A Curve D
- Allen Bradley 1492-SP 1492-SPM MCB 13A Curve C
- Allen Bradley 1492-D2 1492-D MCB 4A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 32A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 6A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 500mA Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 63A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 1.6A Curve C, 10 kA Breaking Capacity