Schneider Electric Acti9 Acti9 iC60 MCB, 2P, 25A, Type AC, 500V AC, 10 mA Breaking Capacity
- RS-artikelnummer:
- 429-217
- Tillv. art.nr:
- A9Q10225
- Tillverkare / varumärke:
- Schneider Electric
Antal (1 enhet)*
6 437,31 kr
(exkl. moms)
8 046,64 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 16 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 6 437,31 kr |
*vägledande pris
- RS-artikelnummer:
- 429-217
- Tillv. art.nr:
- A9Q10225
- Tillverkare / varumärke:
- Schneider Electric
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Schneider Electric | |
| Number of Poles | 2 | |
| Current Rating | 25A | |
| Tripping Characteristics | Type AC | |
| Rated AC Voltage | 500V | |
| Breaking Capacity at Maximum Voltage Rating | 10 mA | |
| Range | Acti9 | |
| Series | Acti9 iC60 | |
| Välj alla | ||
|---|---|---|
Brand Schneider Electric | ||
Number of Poles 2 | ||
Current Rating 25A | ||
Tripping Characteristics Type AC | ||
Rated AC Voltage 500V | ||
Breaking Capacity at Maximum Voltage Rating 10 mA | ||
Range Acti9 | ||
Series Acti9 iC60 | ||
- COO (Country of Origin):
- FR
The Schneider Electric Acti9 Vigi iC60 is a modular add on residual current devices. It is a 2P, rated current is 25A, operating voltage is 230VAC to 240VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 10mA and a voltage independent technology. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. This product is compliant with IEC 61009-1 and EN 61009-1 standard.
Short circuit and cable overload protection
Electrical shock by indirect contact and fire hazards protection
Degree of protection is IP20 and IP40 in an enclosure
RoHS compliant
Electrical shock by indirect contact and fire hazards protection
Degree of protection is IP20 and IP40 in an enclosure
RoHS compliant
relaterade länkar
- Schneider Electric Acti9 Acti9 iC60 MCB 25A 500V AC, 300 mA Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 63A 500V AC, 1000 mA Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 40A 500V AC, 300 mA Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 63A 500V AC, 30 mA Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 25A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 40A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 63A Curve B 6000 A Breaking Capacity
- Schneider Electric Acti9 Acti9 iC60 MCB 32A Curve B 6000 A Breaking Capacity