Eaton xEffect FAZ MCB, 1P, 12A Curve D, 230V AC, 10 kA Breaking Capacity
- RS-artikelnummer:
- 258-998
- Tillv. art.nr:
- 278581 FAZ-D12/1
- Tillverkare / varumärke:
- Eaton
Antal (1 enhet)*
508,48 kr
(exkl. moms)
635,60 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 02 februari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 508,48 kr |
*vägledande pris
- RS-artikelnummer:
- 258-998
- Tillv. art.nr:
- 278581 FAZ-D12/1
- Tillverkare / varumärke:
- Eaton
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 12A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 230V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Series | FAZ | |
| Välj alla | ||
|---|---|---|
Brand Eaton | ||
Number of Poles 1 | ||
Current Rating 12A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 230V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Series FAZ | ||
- COO (Country of Origin):
- RO
The Eaton Miniature Circuit Breaker from the Moeller series is designed for optimal performance and reliability in branch circuits. Offering a single pole configuration with a robust tripping characteristic of D, it is rated for a current of 12 A. With an impressive rated breaking capacity, this device adeptly handles electrical surges while maintaining functionality within specified temperature limits. An efficient heat dissipation design complements its thoughtful engineering, making it suitable for diverse environmental conditions.
Designed for optimal heat dissipation to prevent overheating
Compliant with multiple international safety standards
IP20 degree of protection safeguards against dust ingress
Current limiting class 3 enhances safety during fault conditions
Integrated thermal stability verification for increased resilience
Compliant with multiple international safety standards
IP20 degree of protection safeguards against dust ingress
Current limiting class 3 enhances safety during fault conditions
Integrated thermal stability verification for increased resilience
relaterade länkar
- Eaton xEffect FAZ MCB 12A Curve D 15 kA Breaking Capacity
- Eaton xEffect MCB 12A Curve D
- Eaton xEffect FAZ MCB 12A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 12A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 12A Curve C 60V DC, 7.5 kA Breaking Capacity
- Eaton xEffect FAZ MCB 12A Curve B 60V DC, 7.5 kA Breaking Capacity
- Eaton xEffect FAZ MCB 12A Curve D 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 12A Curve D 10 kA Breaking Capacity