ABB S802N MCB, 2P, 6A Curve D, 400V AC, 36 kA Breaking Capacity
- RS-artikelnummer:
- 140-677
- Tillv. art.nr:
- 2CCS892001R0061
- Tillverkare / varumärke:
- ABB
Antal (1 enhet)*
2 112,63 kr
(exkl. moms)
2 640,79 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 30 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 2 112,63 kr |
*vägledande pris
- RS-artikelnummer:
- 140-677
- Tillv. art.nr:
- 2CCS892001R0061
- Tillverkare / varumärke:
- ABB
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 2 | |
| Current Rating | 6A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 400V | |
| Breaking Capacity at Maximum Voltage Rating | 36 kA | |
| Series | S802N | |
| Välj alla | ||
|---|---|---|
Brand ABB | ||
Number of Poles 2 | ||
Current Rating 6A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 400V | ||
Breaking Capacity at Maximum Voltage Rating 36 kA | ||
Series S802N | ||
- COO (Country of Origin):
- CH
The ABB high-performance MCB is a 2-pole circuit breaker with a rated current of 6 A. It offers overload and short circuit protection with a maximum breaking capacity of 36kA at 240/415V. Compliant with IEC/EN standards, it is suitable for industrial applications worldwide.
2-pole circuit breaker with a rated current of 6 A
Maximum breaking capacity of 36kA at 240 or 415 V
Overload protection with thermal tripping mechanism
Short circuit protection with electromechanic tripping mechanism
Compliance with IEC/EN standards for industrial use
Fast arc extinction for added application security
Maximum breaking capacity of 36kA at 240 or 415 V
Overload protection with thermal tripping mechanism
Short circuit protection with electromechanic tripping mechanism
Compliance with IEC/EN standards for industrial use
Fast arc extinction for added application security
relaterade länkar
- ABB S802N MCB 6A Curve C 36 kA Breaking Capacity
- ABB S802N MCB 6A Curve B 36 kA Breaking Capacity
- ABB S802N MCB 32A Curve B 36 kA Breaking Capacity
- ABB S802N MCB 32A Curve C 36 kA Breaking Capacity
- ABB S802N MCB 13A Curve D 36 kA Breaking Capacity
- ABB S802N MCB 16A Curve B 36 kA Breaking Capacity
- ABB S802N MCB 8A Curve D 36 kA Breaking Capacity
- ABB S802N MCB 8A Curve B 36 kA Breaking Capacity
