ABB S804N MCB, 4P, 40A Curve C, 690V AC, 36 KA Breaking Capacity
- RS-artikelnummer:
- 140-560
- Tillv. art.nr:
- 2CCS894001R0404
- Tillverkare / varumärke:
- ABB
Antal (1 enhet)*
4 338,49 kr
(exkl. moms)
5 423,11 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 22 januari 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 4 338,49 kr |
*vägledande pris
- RS-artikelnummer:
- 140-560
- Tillv. art.nr:
- 2CCS894001R0404
- Tillverkare / varumärke:
- ABB
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | ABB | |
| Number of Poles | 4 | |
| Current Rating | 40A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 690V | |
| Breaking Capacity at Maximum Voltage Rating | 36 KA | |
| Series | S804N | |
| Välj alla | ||
|---|---|---|
Brand ABB | ||
Number of Poles 4 | ||
Current Rating 40A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 690V | ||
Breaking Capacity at Maximum Voltage Rating 36 KA | ||
Series S804N | ||
- COO (Country of Origin):
- CH
The ABB high-performance MCB is a 4-pole circuit breaker with a C-characteristic. It features cage terminals, a rated current of 40 A, and a maximum breaking capacity of 36kA at 240/415V. Suitable for voltages up to 400/690V, it offers both thermal and electromechanical tripping mechanisms for overload and short circuit protection. Compliant with IEC/EN standards, this MCB is ideal for residential, commercial, and industrial applications globally.
4-pole High Performance Circuit Breaker with C-characteristic
Rated current of 40 A with a maximum breaking capacity of 36kA at 240 or 415 V
Thermal and electromechanical tripping mechanisms for overload and short circuit protection
Compliance with IEC/EN standards for global use
Versatile applications in residential commercial and industrial settings
Rated current of 40 A with a maximum breaking capacity of 36kA at 240 or 415 V
Thermal and electromechanical tripping mechanisms for overload and short circuit protection
Compliance with IEC/EN standards for global use
Versatile applications in residential commercial and industrial settings
relaterade länkar
- ABB S804N MCB 40A Curve B 36 kA Breaking Capacity
- ABB S804N MCB 40A Curve D 36 kA Breaking Capacity
- ABB S804N MCB 6A Curve D 36 kA Breaking Capacity
- ABB S804N MCB 50A Curve B 36 kA Breaking Capacity
- ABB S804N MCB 50A Curve C 36 kA Breaking Capacity
- ABB S804N MCB 8A Curve C 36 kA Breaking Capacity
- ABB S804N MCB 8A Curve D 36 kA Breaking Capacity
- ABB S804N MCB 63A Curve D 36 kA Breaking Capacity