Megger LTW315-EU-BS Loop Impendance Tester, Loop Impedance Test Type 2 Wire, 3 Wire 440V, RCD Test Type AC Selective,
- RS-artikelnummer:
- 237-899
- Tillv. art.nr:
- LTW315-EU-BS
- Tillverkare / varumärke:
- Megger

Se alla Loop & RCD Testers
9 I lager för leverans inom 3-5 arbetsdagar
Pris (ex. moms) Each
9 334,52 kr
(exkl. moms)
11 668,15 kr
(inkl. moms)
Enheter | Per unit |
1 + | 9 334,52 kr |
- RS-artikelnummer:
- 237-899
- Tillv. art.nr:
- LTW315-EU-BS
- Tillverkare / varumärke:
- Megger
Lagstiftning och ursprungsland
RoHS-status: Inte relevant
- COO (Country of Origin):
- GB
Produktdetaljer
LTW 300 Series
Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages.
Backlit display
0.01Ω resolution
No-trip loop test on circuits with RCDs of ≥30 mA
3 phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available.
10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected; no need to press the test button means much safer testing
PFC Display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding.
IP54 Weatherproof case
Optional 10A fused 2 wired test leads and crocodile clip set
Complies with IEC61010-1 300V CATIV safety standard and meets EN61557
0.01Ω resolution
No-trip loop test on circuits with RCDs of ≥30 mA
3 phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available.
10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected; no need to press the test button means much safer testing
PFC Display up to 20kA
Voltage and frequency measurement
110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding.
IP54 Weatherproof case
Optional 10A fused 2 wired test leads and crocodile clip set
Complies with IEC61010-1 300V CATIV safety standard and meets EN61557
Note
RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warranty
Supplied with
Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.
Megger Loop Impedance Tester, Backlit Display, 0.01Ω Resolution - LTW300 Series - LTW315-EU-BS
Need to confirm the effectiveness of a fuse or circuit breaker? Choose this Megger loop impedance tester. By attaching its leads to your test equipment, you can determine whether your protective device will be triggered in the event of a fault of up to 20kA. This product has a wide operating temperature range between -10°C and +50°C, so it can handle the heat in harsh work areas. A backlit display means you're not left in the dark when viewing results in dimly lit environments.
Features & Benefits
Carry case has an IP54 rating, so it's protected against limited amounts of dust and water sprays
High accuracy of ±5% at 230V AC for precise results
Battery life allows for 2000 consecutive tests for long-lasting performance
Auto-start function for safe and contact-free testing
High accuracy of ±5% at 230V AC for precise results
Battery life allows for 2000 consecutive tests for long-lasting performance
Auto-start function for safe and contact-free testing
Applications
Circuit breakers
Electrical installations
Distribution boards
Power generation
Electrical installations
Distribution boards
Power generation
What's the operating voltage range of this loop impedance tester?
It has a wide operating voltage range of 100 to 280V, so it's a versatile choice for use in low-power systems.
Specifikationer
Attribute | Value |
Loop Impedance Test Type | 2 Wire, 3 Wire |
Calibrated | UKAS |
Test Equipment Type | Earth Loop Impedance Tester |
Maximum Voltage Measurement | 440V |
RCD Test Type | AC Selective |
Best Loop Test Accuracy | ±10% |
RCD Test Current | 4A |
Non-Trip Loop Test | Yes |
Safety Category | CAT IV 300 V, IEC 61010 |
Display Type | LCD |
Battery Life | 2000 Tests |
Battery Type | AA |
Power Source | Battery |
Weight | 1000g |
Maximum Operating Temperature | +50°C |
Safety Category Voltage | 300V |
Length | 203mm |
Minimum Operating Temperature | -10°C |
Height | 78mm |
Model Number p | LTW315 |
Width | 148mm |
Safety Category Level | CAT IV |