Endress+Hauser Nivotester FTL325N Series Vibronic Point Level Detection Level Sensor, DIN Rail, Polycarbonate,
- RS-artikelnummer:
- 287-1759
- Tillv. art.nr:
- FTL325N-F3E3
- Tillverkare / varumärke:
- Endress+Hauser
Antal (1 enhet)*
2 855,16 kr
(exkl. moms)
3 568,95 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 1 enhet(er) är redo att levereras från en annan plats
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 2 855,16 kr |
*vägledande pris
- RS-artikelnummer:
- 287-1759
- Tillv. art.nr:
- FTL325N-F3E3
- Tillverkare / varumärke:
- Endress+Hauser
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Endress+Hauser | |
| Device Type | Vibronic Point Level Detection | |
| Mounting Type | DIN Rail | |
| Body Material | Polycarbonate, Polypropylene | |
| Cable Length | 1000m | |
| Series | Nivotester FTL325N | |
| Välj alla | ||
|---|---|---|
Brand Endress+Hauser | ||
Device Type Vibronic Point Level Detection | ||
Mounting Type DIN Rail | ||
Body Material Polycarbonate, Polypropylene | ||
Cable Length 1000m | ||
Series Nivotester FTL325N | ||
- COO (Country of Origin):
- DE
The ENDRESS+HAUSER switching unit for point level detection in liquid tanks. It is designed for use in hazardous explosion areas, making it suitable for a wide range of applications. This versatile unit can also be used for overfill prevention in tanks with combustible or non-combustible liquids harmful to water. With its two-point control and point level detection capabilities, It is an ideal choice for safety-related systems with requirements for functional safety up to SIL2 in accordance to IEC 61508/IEC 61511. It features a NAMUR input for easy rail mounting or single installation. The temperature range for this unit is -20 to +50°C (-4 to +122°F), and it comes with international explosion protection certificates, overfill prevention WHG, and marine approvals.
Switching unit for point level detection in liquid tanks
Suitable for hazardous explosion areas
Can be used for overfill prevention in tanks with harmful liquids
Two-point control and point level detection capabilities
Functional safety up to SIL2 in accordance to IEC 61508/IEC 61511
NAMUR input for easy rail mounting or single installation
Temperature range from -20 to +50°C (-4 to +122°F)
Comes with international explosion protection certificates, overfill prevention WHG, and marine approvals
Suitable for hazardous explosion areas
Can be used for overfill prevention in tanks with harmful liquids
Two-point control and point level detection capabilities
Functional safety up to SIL2 in accordance to IEC 61508/IEC 61511
NAMUR input for easy rail mounting or single installation
Temperature range from -20 to +50°C (-4 to +122°F)
Comes with international explosion protection certificates, overfill prevention WHG, and marine approvals
relaterade länkar
- Endress+Hauser Nivotester FTL325N Series Vibronic Point Level Detection Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTL325P Series Vibronic Point Level Detection Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTC325 Series Capacitance Point Level Switch Level Sensor Polycarbonate,
- Endress+Hauser Nivotester FTW325 Series Capacitance Level Sensors DIN Rail
- Endress+Hauser Nivotester Series Level Switch Level Sensors DIN Rail, PP Body
- Endress+Hauser FTL43 Series Vibronic Level Switch Level Sensor 316L Body
- Endress+Hauser FTL31 Series Vibronic Level Switch Level Sensor PPSU Body
- Endress+Hauser FTL33 Series Vibronic Level Switch Level Sensor 316L, PPSU Body