Alpha Wire Ecogen Ecowire Series Grey 0.75 mm² Hook Up Wire, 18 AWG, 16/0.25 mm, 305m, MPPE Insulation, 6715 SL001
- RS-artikelnummer:
- 741-8130
- Tillv. art.nr:
- 6715 SL001
- Tillverkare / varumärke:
- Alpha Wire
Antal (1 rulle med 305 meter)*
3 371,28 kr
(exkl. moms)
4 214,10 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 9 enhet(er) från den 22 december 2025
- Dessutom levereras 8 enhet(er) från den 22 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Rulle(ar) | Per rulle | Per meter* |
|---|---|---|
| 1 + | 3 371,28 kr | 11,053 kr |
*vägledande pris
- RS-artikelnummer:
- 741-8130
- Tillv. art.nr:
- 6715 SL001
- Tillverkare / varumärke:
- Alpha Wire
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Alpha Wire | |
| Cross Sectional Area | 0.75 mm² | |
| Sheath Colour | Grey | |
| Cable Shape | Single Core | |
| American Wire Gauge | 18 AWG | |
| Core Strands | 16/0.25 mm | |
| Length | 305m | |
| Insulation Material | MPPE | |
| Outer Diameter | 1.7mm | |
| Voltage Rating | 600 V | |
| Maximum Operating Temperature | +105°C | |
| Minimum Operating Temperature | -40°C | |
| Conductor Material | Tinned Copper | |
| Standards Met | CE, CSA, UL | |
| Wire Style | UL11028 | |
| Series | Ecogen Ecowire | |
| Insulation Wall Thickness | 0.0095in | |
| Shield Type | Unshielded | |
| Number of Strands | 16 | |
| Size of Strands | 0.25 mm | |
| Välj alla | ||
|---|---|---|
Brand Alpha Wire | ||
Cross Sectional Area 0.75 mm² | ||
Sheath Colour Grey | ||
Cable Shape Single Core | ||
American Wire Gauge 18 AWG | ||
Core Strands 16/0.25 mm | ||
Length 305m | ||
Insulation Material MPPE | ||
Outer Diameter 1.7mm | ||
Voltage Rating 600 V | ||
Maximum Operating Temperature +105°C | ||
Minimum Operating Temperature -40°C | ||
Conductor Material Tinned Copper | ||
Standards Met CE, CSA, UL | ||
Wire Style UL11028 | ||
Series Ecogen Ecowire | ||
Insulation Wall Thickness 0.0095in | ||
Shield Type Unshielded | ||
Number of Strands 16 | ||
Size of Strands 0.25 mm | ||
Belden Ecogen Ecowire Series Hook Up Wire, 0.75mm² Cross Sectional Area, Grey Sheath - 6715 SL001
This hook up wire is a highly versatile 0.75mm² electrical wire designed for various applications in the automation, electronics, and electrical industries. It features a single core construction made from tinned copper, ensuring excellent conductivity and durability. With a sheath colour of grey, this unshielded wire is suitable for use in both high and low-temperature environments, operating effectively from -40°C to +105°C.
Features & Benefits
• Complies with UL11028 standards for safety and reliability
• High-voltage rating of 600 VRMS for demanding applications
• Constructed from tinned copper for superior corrosion resistance
• Single core design simplifies installation and enhances flexibility
• MPPE insulation provides dependable high-temperature performance
• Unshielded design reduces weight while maintaining electrical efficiency
• High-voltage rating of 600 VRMS for demanding applications
• Constructed from tinned copper for superior corrosion resistance
• Single core design simplifies installation and enhances flexibility
• MPPE insulation provides dependable high-temperature performance
• Unshielded design reduces weight while maintaining electrical efficiency
Applications
• Suitable for use in electrical panels and control systems
• Utilised in automation equipment for signal and power transmission
• Ideal for wiring in consumer electronics and appliance industries
• Used with connectors in various mechanical assemblies
• Utilised in automation equipment for signal and power transmission
• Ideal for wiring in consumer electronics and appliance industries
• Used with connectors in various mechanical assemblies
What type of insulation material is used for this wire?
The wire features modified polyphenylene ether (MPPE) insulation, ensuring resilience against high temperatures and exposure to various environmental conditions.
How does the wire perform in extreme temperatures?
This wire is designed to operate effectively in a temperature range from -40°C to +105°C, making it suitable for diverse applications that require reliable performance under challenging conditions.
What is the significance of the tinned copper construction?
Tinned copper enhances corrosion resistance, prolonging the wire's life, especially in damp or demanding environments, while maintaining excellent electrical conductivity.
What are the specific dimensions that should be considered for installation?
The outer diameter of the wire is 1.7mm, and it has a standard insulation wall thickness of 0.0095 inches, which helps in assessing compatibility with connectors and conduits.
EcoWire ™
relaterade länkar
- Alpha Wire Ecogen Ecowire Series Green/Yellow 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715
- Alpha Wire Ecogen Ecowire Series Yellow 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 YL001
- Alpha Wire Ecogen Ecowire Series Red 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 RD001
- Alpha Wire Ecogen Ecowire Series Blue 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 BL001
- Alpha Wire Ecogen Ecowire Series White 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 WH001
- Alpha Wire Ecogen Ecowire Series Green 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 GR001
- Alpha Wire Ecogen Ecowire Series Black 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 BK001
- Alpha Wire Ecogen Ecowire Series Brown 0.75 mm² Hook Up Wire 16/0.25 mm MPPE Insulation, 6715 BR001