Honeywell Amplified Airflow Sensor, 1000 cm³/s, AWM40000 Series
- RS-artikelnummer:
- 623-7927
- Tillv. art.nr:
- AWM43300V
- Tillverkare / varumärke:
- Honeywell
Antal (1 enhet)*
2 464,67 kr
(exkl. moms)
3 080,84 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 136 enhet(er) från den 15 december 2025
- Dessutom levereras 2 enhet(er) från den 22 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 2 464,67 kr |
*vägledande pris
- RS-artikelnummer:
- 623-7927
- Tillv. art.nr:
- AWM43300V
- Tillverkare / varumärke:
- Honeywell
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Honeywell | |
| Media Monitored | Dry Gas | |
| Device Type | Amplified | |
| Maximum Flow Rate | 1000 cm³/s | |
| Supply Voltage | 15 V dc | |
| Pipe Diameter Range | 0.246 in | |
| Maximum Pressure | 150psi | |
| Material | Plastic | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | +85°C | |
| Series | AWM40000 | |
| Välj alla | ||
|---|---|---|
Brand Honeywell | ||
Media Monitored Dry Gas | ||
Device Type Amplified | ||
Maximum Flow Rate 1000 cm³/s | ||
Supply Voltage 15 V dc | ||
Pipe Diameter Range 0.246 in | ||
Maximum Pressure 150psi | ||
Material Plastic | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature +85°C | ||
Series AWM40000 | ||
Uppfyller ej RoHS
- COO (Country of Origin):
- CN
Amplified Airflow Sensor AWM40000 Series
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
Features and Benefits
Manifold mount/o-ring sealed
Ceramic flow tube (non-outgassing), 0 to 1000 sccm
High common mode pressure (150 psi ceramic flow tube only)
Operating temperature up to 125°C
High stability at null and full scale
Product Application Information
Damper control for heating, ventilation, and air conditioning systems
Gas analysers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anaesthesia control
Gas metering
Gas chromatography
relaterade länkar
- Honeywell Amplified Airflow Sensor AWM3000 Series
- Honeywell Amplified Airflow Sensor AWM3000 Series
- Honeywell Compensated/Amplified Airflow Sensor AWM700 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell Amplified Airflow Sensor AWM5000 Series
- Honeywell HAF Series Amplified Airflow Sensor for Dry Gas 50 sccm Max
- Honeywell Pressure Sensor 150psi Max Relative Reading