Control transformers, 1-phase, 4AM Series

Use as power, safety or displacement transformers in accordance with the applicable EN norm
High short-term performance
Low switch-on power (switch-on rush)
Protect against short circuits and overloading with motor protection switches on main side
Electrically isolated coils
Screw terminal connectors

Standards

EN 61 558-2-1, EN 61 558-2-2, EN 61 558-2-4 (at U SEC > 50 V AC), EN 61 558-2-6,
VDE 0570

Approvals

CE, UL

Specifikationer
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 230V ac
Power Rating 2.5kVA
Mounting Type DIN Rail
Number of Outputs 1
Length 180mm
Width 194mm
Depth 178mm
Dimensions 180 x 194 x 178mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 29kg
I lager för leverans inom 2 arbetsdagar
Pris (ex. moms) Each
7 468,58 kr
(exkl. moms)
9 335,72 kr
(inkl. moms)
Enheter
Per unit
1 - 4
7 468,58 kr
5 - 9
7 173,79 kr
10 +
6 901,33 kr
Nästa dag-leverans inte möjlig
Related Products
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic ...
Description:
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic enclosureIntegrated fuse protection and thermal cut-out against overloading and short circuitsScrew-type terminals for the connecting leads on input and output sideMeet the requirements of IEC61 558, EN61 558, ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.