TRACOPOWER TEN 40WI DC-DC Converter, 12V dc/ 3.35A Output, 9 → 36 V dc Input, 40W, Through Hole, +85°C Max Temp

Mängdrabatt möjlig

Antal 5 enheter (levereras i ett rör)*

5 544,00 kr

(exkl. moms)

6 930,00 kr

(inkl. moms)

Add to Basket
välj eller skriv kvantitet
I lager
  • 7 enhet(er) är redo att levereras
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter
Per enhet
5 - 91 108,80 kr
10 - 241 074,42 kr
25 - 491 028,83 kr
50 +983,02 kr

*vägledande pris

Förpackningsalternativ:
RS-artikelnummer:
168-355P
Tillv. art.nr:
TEN 40-2412WI
Tillverkare / varumärke:
TRACOPOWER
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla

Brand

TRACOPOWER

Output Voltage

12V dc

Input Voltage Range

9 → 36 V dc

Power Rating

40W

Input Voltage Nominal

24 V dc

Output Current

3.35A

Mounting Type

Through Hole

Isolated

Yes

Number of Outputs

1

Isolation Voltage

1.5kV dc

Depth

10.2mm

Length

50.8mm

Series

TEN 40WI

Load Regulation

±0.5%

Minimum Temperature

-40°C

Maximum Temperature

+85°C

Efficiency

87%

COO (Country of Origin):
TW

Traco 40W Single/Dual Output Regulated Isolated DC-DC Converter - TEN-40WI Series


40W single/dual output regulated isolated DC-DC converters with a wide input voltage range and compact, low profile case. These isolated DC-DC converter modules have a high efficiency allowing an operating temperature range of -40°C to 85°C. Typical applications for these isolated DC-DC converter modules include battery operated equipment and distributed power architectures in communication and industrial electronics.

High power density in 51x51x10 mm metal package
Ultra-wide 4:1 input voltage range
1.5kV input / output isolation
Built-in filter meets EN 55022, Class A and FCC,Level A with external capacitor
Remote On/Off Control
Under voltage lockout, over voltage, over temperature and short circuit protection
Adjustable output voltage ±10%
Shielded metal case with insulated baseplate

Standards

UL 60950-1, EN 60950-1, IEC 60950-1 (Compliance up to 60Vdc input voltage, SELV limit)

Note

Derate above 55°C

Standards

UL 60950-1, EN 60950-1, IEC 60950-1 (Compliance up to 60Vdc input voltage, SELV limit)