Alpha Wire Alpha Essentials Communication & Control Control Cable, 10 Cores, 0.09 mm² 28 AWG, Screened, 100 m, Grey
- RS-artikelnummer:
- 302-9032
- Tillv. art.nr:
- 3310 SL033
- Tillverkare / varumärke:
- Alpha Wire
Antal (1 rulle med 100 meter)*
3 550,78 kr
(exkl. moms)
4 438,48 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
Tillfälligt slut
- Leverans från den 16 mars 2026
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Rulle(ar) | Per rulle | Per meter* |
|---|---|---|
| 1 + | 3 550,78 kr | 35,508 kr |
*vägledande pris
- RS-artikelnummer:
- 302-9032
- Tillv. art.nr:
- 3310 SL033
- Tillverkare / varumärke:
- Alpha Wire
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Alpha Wire | |
| Product Type | Control Cable | |
| Series | Alpha Essentials Communication & Control | |
| Number of Cores | 10 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | Polyvinyl Chloride | |
| Jacket Colour | Grey | |
| Screened/Unscreened | Screened | |
| Cable Length | 100m | |
| Outside Diameter | 5.11 mm | |
| Voltage | 600 V | |
| Minimum Operating Temperature | -55°C | |
| Standards/Approvals | CE | |
| Maximum Operating Temperature | 105°C | |
| Hazardous Area Certification | No | |
| Cable CSA | 0.09 mm² | |
| American Wire Gauge | 28AWG | |
| Fire Behaviour | FT1, FT4, VW-1 | |
| Core Strands | 7 | |
| Välj alla | ||
|---|---|---|
Brand Alpha Wire | ||
Product Type Control Cable | ||
Series Alpha Essentials Communication & Control | ||
Number of Cores 10 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material Polyvinyl Chloride | ||
Jacket Colour Grey | ||
Screened/Unscreened Screened | ||
Cable Length 100m | ||
Outside Diameter 5.11 mm | ||
Voltage 600 V | ||
Minimum Operating Temperature -55°C | ||
Standards/Approvals CE | ||
Maximum Operating Temperature 105°C | ||
Hazardous Area Certification No | ||
Cable CSA 0.09 mm² | ||
American Wire Gauge 28AWG | ||
Fire Behaviour FT1, FT4, VW-1 | ||
Core Strands 7 | ||
RoHS-status: Undantagen
Belden Alpha Essentials Communication & Control Series Control Cable, 10 Cores, 0.09mm² Cross Sectional Area - 3310 SL033
This control cable is a reliable component designed for industrial communication applications. Featuring 10 cores, it utilises a tinned copper conductor for enhanced conductivity. The cable is encased in a grey PVC sheath, ensuring durability and resistance to wear over time. Complying with DEF STAN standards, it is suitable for various demanding environments operating between -55°C and +105°C.
Features & Benefits
• 10 cores provide versatile connectivity options for various applications
• High-performance tinned copper conductors improve signal integrity
• Screened design minimises electromagnetic interference for cleaner signals
• PVC sheath offers excellent resistance to environmental factors
• Capable of operating up to 600V for industrial durability
• High temperature tolerance supports diverse operational conditions
Applications
• Used for control and signal wiring in automation systems
• Ideal for instrumentation where reliability is critical
• Suitable for communication in electrical and mechanical environments
• Compatible with low-voltage circuits, ensuring safe operation
• Utilised in intercom and sound systems for clear audio transmission
What makes the cable suitable for high-temperature environments?
Its insulation material and design allow it to operate reliably within a temperature range of -55°C to +105°C, making it ideal for various industrial applications.
How do I ensure proper installation of the cable in my setup?
Proper installation requires following industry standards and ensuring connections are secure to prevent any signal loss or interference, particularly in high-frequency applications.
Is there a specific application where I should avoid using this cable?
While versatile, it may not be suitable for underwater or harsh chemical environments without additional protective measures, as the PVC sheath may degrade under certain conditions.
What are the benefits of using tinned copper conductors instead of standard copper?
Tinned copper offers better corrosion resistance and maintains conductivity, making it a superior choice for environments where exposure to moisture may occur.
relaterade länkar
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 100 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 100 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 100 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 100 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 100 m, Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² Screened Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² Screened Grey
- Alpha Wire Alpha Essentials Communication & Control Control Cable 0.09 mm² 28 AWG 305 m, Black