ITT Cannon Male Crimp Circular Connector Contact, Contact Size 20, Wire Size 22 → 20 AWG
- RS-artikelnummer:
- 190-3407
- Tillv. art.nr:
- T2P20MC1LZ / 192922-1460
- Tillverkare / varumärke:
- ITT Cannon
Mängdrabatt möjlig
Antal (1 förpackning med 100 enheter)*
646,50 kr
(exkl. moms)
808,10 kr
(inkl. moms)
Lagerinformation är för närvarande otillgänglig
Enheter | Per enhet | Per förpackning* |
|---|---|---|
| 100 - 100 | 6,465 kr | 646,50 kr |
| 200 - 300 | 6,142 kr | 614,20 kr |
| 400 - 500 | 5,715 kr | 571,50 kr |
| 600 + | 5,256 kr | 525,60 kr |
*vägledande pris
- RS-artikelnummer:
- 190-3407
- Tillv. art.nr:
- T2P20MC1LZ / 192922-1460
- Tillverkare / varumärke:
- ITT Cannon
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | ITT Cannon | |
| Gender | Male | |
| Contact Size | 20 | |
| Wire Size | 22 → 20 AWG | |
| Termination Method | Crimp | |
| Series | T2P | |
| For Use With | Trident T2P Contact System | |
| Contact Type | Signal | |
| Contact Plating | Gold | |
| Contact Material | Brass | |
| Minimum Operating Temperature | -55°C | |
| Maximum Operating Temperature | +125°C | |
| Välj alla | ||
|---|---|---|
Brand ITT Cannon | ||
Gender Male | ||
Contact Size 20 | ||
Wire Size 22 → 20 AWG | ||
Termination Method Crimp | ||
Series T2P | ||
For Use With Trident T2P Contact System | ||
Contact Type Signal | ||
Contact Plating Gold | ||
Contact Material Brass | ||
Minimum Operating Temperature -55°C | ||
Maximum Operating Temperature +125°C | ||
Crimp Two Piece Contacts
Use plier or ratchet style tool to crimp contacts.
Current rating (single contact in isolation) 13A
Initial contact resistance 5mΩ
Contact area selectively gold plated
Crimp area tin plated
Up to 200 mating cycles
Initial contact resistance 5mΩ
Contact area selectively gold plated
Crimp area tin plated
Up to 200 mating cycles
QM Range Contacts and Tooling
The current rating quoted is for a single contact pair in isolation; when more than one pair of contacts in a connector is carrying appreciable current, the maximum permissible current per contact must be reduced to take the cumulative heating effect into account. This multi-way de-rating factor is established from similar factors established for multi-core cables.