RS PRO 150VA 1 Output Chassis Mounting Transformer, 12V ac, IEC 61558-2-6
- RS-artikelnummer:
- 504-177
- Tillverkare / varumärke:
- RS PRO
Mängdrabatt möjlig
Antal (1 enhet)*
1 757,39 kr
(exkl. moms)
2 196,74 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- Dessutom levereras 39 enhet(er) från den 15 december 2025
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 - 24 | 1 757,39 kr |
| 25 + | 1 609,89 kr |
*vägledande pris
- RS-artikelnummer:
- 504-177
- Tillverkare / varumärke:
- RS PRO
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | RS PRO | |
| Primary Voltage Rating | 230 V ac, 245 V ac, 400 V ac, 415V ac | |
| Secondary Voltage Rating | 12V ac | |
| Power Rating | 150VA | |
| Number of Outputs | 1 | |
| Mounting Type | Panel | |
| Primary Winding Resistance | 7/17.8Ω | |
| Length | 108mm | |
| Efficiency | 87% | |
| Width | 114mm | |
| Depth | 110mm | |
| Dimensions | 108 x 114 x 110mm | |
| Fixing Hole Diameter | 6.5mm | |
| Weight | 3.5kg | |
| Minimum Operating Frequency | 50Hz | |
| Standards Met | IEC 61558-2-6 | |
| Maximum Operating Frequency | 60Hz | |
| Maximum Temperature | (Ambient) 70°C | |
| Minimum Temperature | -30°C | |
| Välj alla | ||
|---|---|---|
Brand RS PRO | ||
Primary Voltage Rating 230 V ac, 245 V ac, 400 V ac, 415V ac | ||
Secondary Voltage Rating 12V ac | ||
Power Rating 150VA | ||
Number of Outputs 1 | ||
Mounting Type Panel | ||
Primary Winding Resistance 7/17.8Ω | ||
Length 108mm | ||
Efficiency 87% | ||
Width 114mm | ||
Depth 110mm | ||
Dimensions 108 x 114 x 110mm | ||
Fixing Hole Diameter 6.5mm | ||
Weight 3.5kg | ||
Minimum Operating Frequency 50Hz | ||
Standards Met IEC 61558-2-6 | ||
Maximum Operating Frequency 60Hz | ||
Maximum Temperature (Ambient) 70°C | ||
Minimum Temperature -30°C | ||
- COO (ursprungsland):
- PL
Control Panel Primary 230/ 400Vac with +15Vac Tap
"High quality safety and isolating transformers designed for use in control circuits and general applications
Low loss noise laminations
Dual standard primary winding 230 / 400 Vac with +15V tap for input flexibility
Dual secondaries are centre tapped. Earth terminal provided
Varnish impregnated for overall protection against humidity and rusting
Fully shrouded cage clamp terminal with voltage markings
Detailed product specification on permanent label
High efficiency, low regulation design"
"High quality safety and isolating transformers designed for use in control circuits and general applications
Low loss noise laminations
Dual standard primary winding 230 / 400 Vac with +15V tap for input flexibility
Dual secondaries are centre tapped. Earth terminal provided
Varnish impregnated for overall protection against humidity and rusting
Fully shrouded cage clamp terminal with voltage markings
Detailed product specification on permanent label
High efficiency, low regulation design"
Standards
BS EN 61558
Laminated
relaterade länkar
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-6
- RS PRO 150VA 2 Output Chassis Mounting Transformer IEC 61558-2-4
- RS PRO 150VA 1 Output Chassis Mounting Transformer IEC 61558-2-4