An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.Things to consider when choosing probes Ensure the probe's input connector matches the connector on your scope Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracyThe best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor. The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probeTypes of probesPassive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations: 1´: no attenuation 10´: factor-of-10 attenuation 100´: factor-of-100 attenuation 1000´: factor-of-1000 attenuationAttenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons: It allows for the measurement of a signal that might exceed the limits of the oscilloscope. The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range. Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.A current probe measures the electrical current flowing through a conductor. Tips Always use an appropriate probe tip and/or probe tip adapter whenever possible Keep ground leads short

...
Read more Read less

Filter

Visar 1 - 19 av 19 produkter
Resultat per sida
Beskrivning Pris Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Series Safety Category Rise Time
RS-artikelnummer 733-6141
Tillv. art.nrN2790A
14 707,00 kr
Each
Enheter
Differential, High Voltage 1:50, 1:500 100MHz 1.4kV BNC N2790A - CAT II, CAT III 600 V, 1000 V N CAT II 1000 V, CAT III 600 V 3.5ns
RS-artikelnummer 702-7910
Tillv. art.nr11060A
316,34 kr
Each
Enheter
Surface Mount Device - - - - 11060A - - - - - -
RS-artikelnummer 733-6145
Tillv. art.nrN2791A
6 131,00 kr
Each
Enheter
Differential 1:10, 1:100 25MHz 700V BNC N2791A - CAT II 1000V ac N CAT II 1000 V ac 14ns
RS-artikelnummer 733-6148
Tillv. art.nrN2796A
20 985,00 kr
Each
Enheter
Active 1:10 2GHz - - N2796A - - - N - 175ps
RS-artikelnummer 702-3895
Tillv. art.nrN2870A
2 272,00 kr
Each
Enheter
Passive 1:1 35MHz - BNC N2870A - CAT II 55V N287XA CAT II 55V -
RS-artikelnummer 733-6139
Tillv. art.nrN2795A
10 350,00 kr
Each
Enheter
Active 1:10 1GHz - - N2795A - - - N - 350ps
RS-artikelnummer 733-6132
Tillv. art.nrN2889A
1 299,00 kr
Each
Enheter
Passive 1:1, 1:10 350MHz - BNC N2889A - CAT I, CAT II 150 V ac, 300 V ac N28XXA/B CAT I 15 V ac, CAT I 300 V ac, CAT II 15 V ac, CAT II 300 V ac 1 ns, 35 ns
RS-artikelnummer 667-2604
Tillv. art.nrU1561A
1 335,00 kr
Each
Enheter
Passive 1:10 250MHz - - U1561A - CAT III 600V - CAT III 600 V -
RS-artikelnummer 185-2140
Tillv. art.nrN2843A
1 850,86 kr
Each
Enheter
Passive 10:1 500MHz - - N2843A 1 CAT II - - CAT II 300 Vrms 700ps
RS-artikelnummer 134-6157
Tillv. art.nrN2142A
515,00 kr
Each
Enheter
Passive 1:1, 1:10 75MHz - BNC 1000/3000 X-Series 1 CAT II 150 Vrms, 300 Vrms InfiniiVision CAT II 150 Vrms, CAT II 300 Vrms -
RS-artikelnummer 702-3918
Tillv. art.nrN2876A
4 134,00 kr
Each
Enheter
Passive 1:100 1.5GHz - BNC N2876A - CAT I 21V N2870A CAT I 21 V -
RS-artikelnummer 501-180
Tillv. art.nr10072A
1 396,74 kr
Each
Enheter
Gripper - - - - 10072A - - - - - -
RS-artikelnummer 667-2608
Tillv. art.nrU1562A
1 467,00 kr
Each
Enheter
Passive 1:100 300MHz - - U1562A - CAT III 600V - CAT III 600 V -
RS-artikelnummer 702-3906
Tillv. art.nrN2874A
4 134,00 kr
Each
Enheter
Passive 1:10 1.5GHz - BNC N2874A - CAT I 8.5V N2870A CAT I 8.5V -
RS-artikelnummer 714-0035
Tillv. art.nr10074D
1 929,00 kr
Each
Enheter
Passive 1:10 150MHz - BNC 10074D - CAT I, CAT II 400 V, 500 V - CAT I 500 V, CAT II 400 V 2.33ns
RS-artikelnummer 134-6158
Tillv. art.nrN2140A
702,00 kr
Each
Enheter
Passive 1:1, 1:10 200MHz - BNC 1000/3000 X-Series 1 CAT II 150 Vrms, 300 Vrms InfiniiVision CAT II 150 Vrms, CAT II 300 Vrms -
RS-artikelnummer 714-0039
Tillv. art.nr10073D
3 713,00 kr
Each
Enheter
Passive 1:10 500MHz - BNC 10073D - CAT II 400V - CAT II 400 V 700ps
RS-artikelnummer 702-3899
Tillv. art.nrN2871A
2 476,00 kr
Each
Enheter
Passive 1:10 200MHz - BNC N2871A - CAT I, CAT II 300 V, 400 V N2870A CAT I 400 V, CAT II 300 V -
RS-artikelnummer 702-3902
Tillv. art.nrN2873A
3 622,00 kr
Each
Enheter
Passive 1:10 500MHz - BNC N2873A - CAT I, CAT II 300 V, 400 V N2870A CAT I 400 V, CAT II 300 V -