18V dc 1 Output Through Hole PCB Transformer, 7.5W

  • RS-artikelnummer 869-5035
  • Tillv. art.nr 47204
  • Tillverkare / varumärke Myrra
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): CN
Produktdetaljer

Single Regulated DC Output Electronic Transformers

MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology
They are an interesting alternative to the traditional supply in the most common applications of power lower than 5W
ENERGY SAVING due to high efficiency and low standby power
The applications for the Electronic series are, telecom supplies, electric substations etc. Industrial, domestic and consumer electronics
With the same footprint as a EI30 transformer, they will replace the 50 Hz Transformer, Fuse, Bridge Rectifier, Regulator and Filtering Capacitor

Specifikationer
Attribute Value
Secondary Voltage Rating 18V dc
Power Rating 7.5W
Primary Voltage Rating 85 → 265 V ac, 120 → 370 V dc
Number of Outputs 1
Mounting Type Through Hole
Minimum Temperature -25°C
Maximum Temperature +70°C
Minimum Operating Frequency 47Hz
Maximum Operating Frequency 63Hz
I lager för leverans inom 2 arbetsdagar
Pris (ex. moms) Each
125,63 kr
(exkl. moms)
157,04 kr
(inkl. moms)
Enheter
Per unit
1 - 9
125,63 kr
10 - 24
122,43 kr
25 +
112,91 kr
Nästa dag-leverans inte möjlig
Related Products
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).