15V ac 2 Output Through Hole PCB Transformer, 12VA

  • RS-artikelnummer 504-442
  • Tillverkare / varumärke RS PRO
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): PL
Produktdetaljer

PCB Mount 115/230Vac Transformer

Twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation
Fully shrouded bobbins
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742

//media.rs-online.com/t_line/L231852-01.gif

Approvals

8888

Standards

BS3535; EN 60 742

Open Frame - Laminated

PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.

Double section metric bobbin constructionFull varnish impregnation

Specifikationer
Attribute Value
Secondary Voltage Rating 15V ac
Power Rating 12VA
Primary Voltage Rating 115 V ac, 230 V ac
Number of Outputs 2
Length 54mm
Width 45mm
Depth 41mm
Dimensions 54 x 45 x 41mm
Weight 400g
Mounting Type Through Hole
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
112 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
120,87 kr
(exkl. moms)
151,09 kr
(inkl. moms)
Enheter
Per unit
1 - 9
120,87 kr
10 - 24
93,99 kr
25 - 49
89,03 kr
50 +
81,89 kr
Related Products
This range of covered (up to 320 VA) ...
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).