Eaton Current Monitoring Relay With DPDT Contacts, 1 Phase, 220 → 240 V ac

  • RS-artikelnummer 102-6140
  • Tillv. art.nr 106944
  • Tillverkare / varumärke Eaton
Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): DE
Produktdetaljer

EMR4 Series

Professional range of Eaton current monitoring relays from the EMR4 series. The main function of the relays is the monitoring of single phase AC and DC networks. The relays are designed to cover a wide range of applications in electrical switchgear technology such as multifunctional 3 phase monitors and earth leakage monitors.

Test button
LED status indication

Eaton Monitoring Relay

Specifikationer
Attribute Value
Monitoring Application Current
Supply Voltage 220 → 240 V ac
Contact Configuration DPDT
Electrical Phase 1
Current Sensitivity Overcurrent, Undercurrent
Minimum Current Sensed 0.3 (B1) A, 1 (B2) A, 3 (B3) A
Maximum Current Sensed 1.5 (B1) A, 5 (B2) A, 15 (B3) A
Time Delay 0.1 → 30 s
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Height 100mm
Mounting Type DIN Rail
Terminal Type Screw
Operating Temperature Range -20 → +60 °C
Width 78mm
Length 22.5mm
Series EMR4
Standards Met CE Certified, CSA-22.2, EN 55022, IEC 255-6, IEC 60947-5-1, IEC 664, IEC 947-1, IEC/EN 60068-2-30, IEC/EN 60255-21-1, IEC/EN 60255-21-2, IEC/EN 60255-5, IEC/EN 60255-6, IEC/EN 60947-1, IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN 61000-4-4, IEC/EN 61000-4-6, IEC/EN 61000-4-9, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL, UL 508, UL Listed, VDE 0110, 2004/108/EC, 2006/95/EC, 3211-03
Dimensions 22.5 x 78 x 100 mm
Number of Poles 1
Current Range 0.3 → 1.5 (B1) A, 1 → 5 (B2) A, 3 → 15 (B3) A
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
2 034,23 kr
(exkl. moms)
2 542,79 kr
(inkl. moms)
Enheter
Per unit
1 +
2 034,23 kr
Related Products
Schneider Electric RM17 U single-phase and direct current ...
Description:
Schneider Electric RM17 U single-phase and direct current voltage control relays that monitor over-voltage and under-voltage, with or without memory, or that operate in window mode. The overvoltage and undervoltage threshold values are adjusted via two graduated potentiometers that directly ...
Use: overcurrent monitoring in DC and AC current ...
Description:
Use: overcurrent monitoring in DC and AC current networksFour measurement ranges that can be set via a rotary switchAdjustable response value, fixed hysteresisAdjustable switching delayRest current principleLED display for associated auxiliary voltage and activated output relay230 VAC auxiliary voltageAuxiliary ...
Monitors 1-phase & 3-phase supply voltages for phase ...
Description:
Monitors 1-phase & 3-phase supply voltages for phase failure. On fault, relay de-energizes & yellow LED turns off5% fixed hysteresis0.5 sec fixed OFF delay.
, Monitoring of DC- and AC-currents: CM-SRS.x1: 3mA ...
Description:
, Monitoring of DC- and AC-currents: CM-SRS.x1: 3mA - 1A and CM-SRS.x2: 0.3-15ARMS measuring principleOne device includes 3 measuring rangesOver- or undercurrent monitoring configurableHysteresis adjustable from 3-30%Tripping delay TV adjustable 0.1-30sCM-SRS.1: 1 c/o contactCM-SRS.2: 2 c/o contacts22.5mm width3 ...