Broyce Control Phase Monitoring Relay, 3 Phase, 300 500 V ac

  • RS-artikelnummer 629-386
  • Tillv. art.nr M3PPI 300-500vAC
  • Tillverkare / varumärke Broyce Control
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): GB
Produktdetaljer

Phase Sequence/ Failure Monitoring Indicator

The M3PPI is a DIN Rail mount Phase Monitoring Indicator designed for 3-phase, 3-wire supplies. It is used to indicate the presence of each phase and whether the phase sequence is correct or not.

//media.rs-online.com/t_line/L342944-01.gif

Phase Sequence/Failure Relays

Monitoring of 3 phase supplies
Orange housing manufactured to DIN 43 880
DIN rail mount

Specifikationer
Attribute Value
Monitoring Application Phase
Supply Voltage 300 500 V ac
Electrical Phase 3
Phase Sensitivity Phase Loss, Phase Sequence
Minimum Operating Temperature -20°C
Dimensions 59 x 35 x 89 mm
Length 59mm
Width 35mm
Operating Temperature Range -20 +60 °C
Height 89mm
Maximum Operating Temperature +60°C
Tillfälligt slut i lager – restorder för leverans 2020-02-21
Pris (ex. moms) Each
505,10 kr
(exkl. moms)
631,38 kr
(inkl. moms)
Enheter
Per unit
1 +
505,10 kr
Related Products
3 Phase Voltage Monitoring Relay with NO/NC Contact ...
Description:
3 Phase Voltage Monitoring Relay with NO/NC Contact Configuration. Features & BenefitsIncorrect Phase SequencePhase lossPhase undervoltage (0.6 x Un)Adjustable fault delayLED indicationWrite on ID tabDimensions: H78 x W45 x D99mm.
Separate relay & LED operation for three phase ...
Description:
Separate relay & LED operation for three phase monitoring 'V' & thermistor monitoring 'T'The relay monitors the following:Incorrect phase sequence/rotationThreshold voltage 60% of 400VacPhase failure/lossPhase under-voltage (0.6 x 400Vac)Thermistor over-temperatureThermistor open circuitThermistor short ...
Detects over-current conditionAdjustment for trip levelMonitors current in ...
Description:
Detects over-current conditionAdjustment for trip levelMonitors current in 3-phase supplyTime delay (from fault) with adjustable setting: 0.2 to 10s1 x DPDT relay output 8ALED indication for supply and relay statusDIN rail or surface mountDimensions: H70 x W100 x D112mm.
Detects under and over-voltage conditionAdjustment for under and ...
Description:
Detects under and over-voltage conditionAdjustment for under and over trip levelsAdjustable hysteresisMonitors own supplySeparate relays for under and overTime delay: 200 ms (from fault)2 x DPDT relay output 8ALED indication for supply and relay statuses70 mm housing, DIN Rail or ...