KANE450-201 KIT/RS Flue Gas Analyser

  • RS-artikelnummer 146-777
  • Tillv. art.nr KANE450 KIT/RS
  • Tillverkare / varumärke Kane
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): GB
Produktdetaljer

KANE Gas Analyser

The Kane 450-201 flue gas analyser has an easy-to-use rotary switch and includes all the features expected from a top-of-the-range analyser. Any four parameters can be displayed simultaneously. The high accuracy and stability of its pressure readings allow difficult tasks such as measuring flue draught and checking the air\fuel ratio valve on high-efficiency boilers to be performed with confidence. It is fitted with a 0 to 4,000ppm CO sensor and is suitable for commercial and domestic boilers.
Supplied with:
Protective rubber sleeve with a magnet, flue probe, rechargeable batteries, 220V charger, infrared printer, pressure connectors and carry case.

Features and Benefits

• Four line backlit display controlled by a rotary switch
• Measures O2, CO, temperature and pressure
• Extra protection and hands-free operation
• Optional Bluetooth upgrade
• Quick start feature for temperature and pressure readings
• High accuracy differential manometer
• Differential thermometer for flow/return/ΔT
• Hold, store and auto-store readings
• Reports include combustion test, tightness test, CO build-up and differential temperature
• Infrared output to a thermal paper printer
• Torchlight
• Connection for optional gas leak detector
• Designed to meet BS7927, EN 50379 and BS7967
• Battery life typically is 12+ hours from full charge
• Large display with backlight
• Carbon monoxide resolution is 1ppm
• Carbon dioxide resolution is 0.1%
• Oxygen level resolution is 0.1%
• Gas pressure resolution is 0.01mbar, 0.1Pa, 1Pa
• Temperature measurement resolution is 1°C
• Temperature sensor is Type-K
• Pre-programmed fuels are butane, light oil, LPG, natural gas, propane
• Maximum oxygen level is 21%
• Maximum gas pressure is 20mbar, 80mbar, 100mbar, 2000mbar
• Minimum gas pressure is -2000mbar, -100mbar, -80mbar, -20mbar
• Minimum oxygen level is 0%
• Battery life of 12 hours

Applications

• Installation, commissioning & service of domestic & commercial oil, gas biomass appliances
• Safety checks CO in a room or around an appliance
• Combustion performance checks
• Combustion efficiency checks
• Flue Draught

Certifications

• BS7927
• EN 50379
• BS7967

Standards

BS7927; EN 50379; BS7967

Specifikationer
Attribute Value
Gases Detected Carbon Dioxide, Carbon Monoxide, Oxygen
Best Carbon Monoxide Accuracy ±10ppm
Carbon Monoxide Resolution 1ppm
Best Carbon Dioxide Accuracy ±0.3%
Carbon Dioxide Resolution 0.1%
Best Oxygen Level Accuracy ±0.2%
Oxygen Level Resolution 0.1%
Best Gas Pressure Accuracy ±0.5Pa
Gas Pressure Resolution 0.01 mbar, 0.1 Pa, 1 Pa
Best Temperature Measurement Accuracy ±1 °C
Temperature Measurement Resolution 1°C
Temperature Sensor Type K
Pre-Programmed Fuel Type Butane, Light Oil, LPG, Natural Gas, Propane
Height 90mm
Maximum Operating Temperature +40°C
Minimum Operating Temperature 0°C
Power Source Battery
Display Type LCD
Length 200mm
Maximum Oxygen Level 21%
Minimum Carbon Dioxide Level 0%
Maximum Gas Pressure +20 mbar, +80 mbar, +100 mbar, +2000 mbar
Minimum Carbon Monoxide Level 0ppm
Model Number p KANE450 KIT
Maximum Carbon Dioxide Level 30%
Maximum Carbon Monoxide Level 4000ppm
Minimum Gas Pressure -2000 mbar, -100 mbar, -80 mbar, -20 mbar
Dimensions 200 x 45 x 90mm
Battery Type AA x 4
Width 45mm
Battery Life 12 h
Weight 770g
Minimum Oxygen Level 0%
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
10 673,36 kr
(exkl. moms)
13 341,70 kr
(inkl. moms)
Enheter
Per unit
1 +
10 673,36 kr
Related Products
Two kits of iglidur® G dry bushes and ...
Description:
Two kits of iglidur® G dry bushes and thrust washers, offering cost-effective solutions for a variety of applications requiring compact, low-friction bearings. iglidur® G is the 'all rounder' polymer bearing, having low friction, high wear resistance and high load capacity. ...
Datalogger kit with one integral temperature/RH measurement data ...
Description:
Datalogger kit with one integral temperature/RH measurement data logger.Ideal for many applications including food, pharmaceutical and chemical industries, building services, production processes and heating, ventilating and air conditioning systems,The N2013 data logger kits packages a N2013 integral ...
The Tetra range of multi-gas personal detectors is ...
Description:
The Tetra range of multi-gas personal detectors is ideal for users working in hazardous or confined environments with potential exposure to a range of toxic and flammable gases. 2, 3 or 4 gas versions available (Flammable FL, Oxygen O2, Hydrogen ...
Carbon Monoxide is a deadly toxic gas that ...
Description: