Phoenix Contact PACT RCP-4000A-1A-D95 Series Current Sensor, 100 → 4000A, 0 → 1A output current

  • RS-artikelnummer 820-0431
  • Tillv. art.nr 2904921
  • Tillverkare / varumärke Phoenix Contact
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): DE
Produktdetaljer

PACT RCP - Current Transformer

The PACT RCP Current Transformer Kit for retrofitting for alternating currents up to 4000 Aac.

Current Transformer Kit

Kit consisting of 2 components: 1 A measuring transducer and a Rogowski coil
High system availability due to easy installation without removing system parts
Transform alternating currents up to 4000 A using a single measuring system
Space saving and handy: the current strength does not affect the size and weight of the coil
Safe installation and operation: no dangerous open circuit voltages
Harmonics and transients detected with phase accuracy with a large frequency range from 10 to 5000 Hz
Rogowski coil secured on power rails and circular conductors, plus high measuring accuracy, thanks to rofessional holding device
A holder for the coil is also available (stock-no.: 820-0447)

Measuring Transducer

Measuring transducer processes the mV signal of the upstream Rogowski coil
8 current measuring ranges (100 - 4000 Aac) which can be set via DIP switches
Max. output current of 1 Aac
Power supply 19.2 – 30 Vdc
Power consumption 4W

Rogowski Coil

The Rogowski coil is used for AC current measurement for busbars and power lines
The coil is available in different length and diameters:
Length: 300 mm, diameter when installed: 95 mm, stock-no.: 820-0431
Length: 450 mm, diameter when installed: 140 mm, stock-no.: 820-0435
Length: 600 mm, diameter when installed: 190 mm, stock-no.: 820-0444

Holder

The optional holder ensures the Rogowski coil is securely seated on busbars with a thickness of 5-15 mm
During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically
Stock-no is 820-0447

Phoenix Contact Current Transducer

Specifikationer
Attribute Value
Nominal Current 100 → 4000A
Output Current Range 0 → 1A
Supply Voltage 24 V dc
Mounting Type Flange Mount
Frequency Bandwidth 10 → 5000 Hz, 45 → 65 Hz
Accuracy ±0.21 %
Bore Size 8.3mm
Minimum Operating Temperature -30°C
Series PACT RCP-4000A-1A-D95
Maximum Operating Temperature +80°C
Depth 85mm
Height 70.4mm
Width 22.5mm
7 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
2 917,41 kr
(exkl. moms)
3 646,76 kr
(inkl. moms)
Enheter
Per unit
1 - 4
2 917,41 kr
5 +
2 798,98 kr
Related Products
DIN rail adapter for head-mounted transducers. Suitable for ...
Description:
DIN rail adapter for head-mounted transducers. Suitable for 35 mm DIN rails.
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.
MACX MCR-SL-CAC series current measuring transducers. 3 way ...
Description:
MACX MCR-SL-CAC series current measuring transducers. 3 way isolationInput/output signal can be configured using the DIP switchOperating state indication via LEDScrew terminal block.
The SICK LED contrast sensor is KTS core ...
Description: